LC-22LE250
LC-24LE250
STBY_ON/OFF_NOT should be low for tv on condition, please check Q11's collector.
B. CI Module Problem
Problem: CI is not working when CI module inserted.
Possible couses: Supply, suply control pin, detect pins, mechanical positions of pins.
•
CI supply should be 5V when CI module inserted. If it is not 5V please check
CI_PWR_CTRL, this pin should be low.