Step 3. Installing The Power Cord - Samsung NE58R9311 Installation Manual

Table of Contents

Advertisement

Available languages

Available languages

Specified rating of power-supply-cord kit and circuit
protection
Range rating, watts
120/240 volts
3-wire
8750 - 16500
This appliance must be supplied with the proper voltage at the proper frequency
and must be connected to a dedicated, properly grounded branch circuit protected
by a 40 amp or larger circuit breaker.
NOTE
go to page 13.

STEP 3. INSTALLING THE POWER CORD

For power cord installations, hook the strain relief over the power cord hole (1
located below the rear of the drawer body. Insert the power cord through the strain
relief and tighten the device.
Power cord
• You must install the power cord with a strain relief.
• Attach the strain relief to the 1
Install_NE58H9970WS_AA_AC_DG68-00594B-00_EN+CFR.indb 10
Specified rating
of power-supply-
cord kit and circuit
120/208 volts
protection, Amps
3-wire
7801 - 12500
40 or 50 A
For power cord installations, go to page 10. For conduit installations,
Conduit connection plate
Strain relief
/
" opening in the conduit connection plate.
3
8
English - 10
Diameter (inches) of range
connection opening
Power cord
Conduit
1
/
"
1
/
"
3
1
8
8
/
3
8
6/7/2019 12:45:43 PM
")