Setting Menus

The functions and parameters of the settings menu are
explained here. Underlined items are the factory setting.
Unit name setting
You can specify a transmitter name of up to 16 characters.
The factory setting for the transmitter name is the model
name and serial number. The transmitter name is sent to
the receiver as metadata and is used by the receiver to
distinguish between different transmitters.
+: The first press on the + button displays the character set.
You can then use the + and – buttons to select the desired
character. And then, pressing the SET button adds the
selected character to the end of the current name.
– : Deletes the last character in the current name.
SET: Enters the character or edited name.
Note
You cannot insert or delete a character in the middle of the
name.
Using wireless remote control, this function can be
controlled from the receiver and other devices.
For details on wireless remote control function, see
"Using Cross Remote" (page 7).
Selecting the frequency band
Match the frequency range on this transmitter to that of the
Sony digital wireless receiver.
See "Carrier Frequencies and Channel Steps" (page 20)
for differences in frequency ranges that can be set for
optional receivers combined with this transmitter.
For details on groups and channels included in each
frequency band, refer to the frequency lists.
Using wireless remote control, this function can be
controlled from the receiver and other devices.
For details on wireless remote control function, see
"Using Cross Remote" (page 7).
Notes
• The setting for this function cannot be changed during
actual signal transmission. To change the setting, turn
off the transmitter first. Then, while holding down the
SET button, turn the power on. Then change the setting
after the signal transmission has stopped.
• Be sure to select the group/channel right after selecting
the frequency band. To start signal transmission with the
selected frequency band/group/channel, turn off the
power and then turn it on again.
(NAME)
(BAND)
Selecting the group/channel
See "Carrier Frequencies and Channel Steps" (page 20)
for factory settings.
For details, see "Selecting the group/channel" (page 6).
Using wireless remote control, this function can be
controlled from the receiver and other devices.
For details on wireless remote control function, see
"Using Cross Remote" (page 7).
Audio attenuator setting
When INPUT LEVEL is set to MIC, select the attenuator
level for audio inputs.
Note
This setting cannot be changed when INPUT LEVEL is set
to LINE.
Input audio from the connected microphone, and use the +
and – buttons to select the attenuator level while viewing
the input level meter.
The reference levels for the various settings are as follows.
Input
Attenuation
Reference
(dB)
input level
(dBu)
MIC
0
–58
3
–55
6
–52
9
–49
3 dB steps
3 dB steps
45
–13
48
–10
LINE
+4
The audio attenuator setting can be changed from the
receiver and other devices via the wireless remote control
function.
For details, see "Using Cross Remote" (page 7).
Low-cut filter setting
The frequency of the low-cut filter can be set.
OFF: Turns off the low-cut filter.
20 30 40 50 60 70 80 90 100
120 140 160 180 200 220 (Hz): Low-cut filter is set
according to the selected frequency.
Using wireless remote control, this function can be
controlled from the receiver and other devices.
For details on wireless remote control function, see
"Using Cross Remote" (page 7).
10
(GP/CH)
(AF ATT)
Maximum
Headroom
input level
(dB)
(dBu)
–22
36
–19
–16
–13
3 dB steps
+23
+24
34
+24
20
(LCF)