5 Service Mode
5.1.
How to enter into Service Mode
5.1.1.
Purpose
After exchange parts, check and adjust the contents of adjustment mode.
While pressing [VOLUME ( - )] button of the main unit, press [INFO] button of the remote control three times within 2 seconds.
Contents of adjustment mode
5.1.2.
• Value is shown as a hexadecimal number.
• Preset value differs depending on models.
• After entering the adjustment mode, take note of the value in each item before starting adjustment.
WB-ADJ
OPTION
5.1.3.
How to exit
Switch off the power with the [POWER] button on the main unit or the [POWER] button on the remote control.
5.1.4.
Display of SOS History
SOS History (Number of LED blinking) indication.
From left side; Last SOS, before Last, three occurrence before, 2nd occurrence after shipment, 1st occurrence after shipment.
This indication except 2nd and 1st occurrence after shipment will be cleared by [Self-check indication and forced to factory
shipment setting].
5.1.5.
POWER ON TIME/COUNT
Note : To display TIME/COUNT menu, highlight position, then press MUTE for 3sec.
Time : Cumulative power on time, indicated hour : minute by decimal
Count : Number of ON times by decimal
Note : This indication will not be cleared by either of the self-checks or any other command.
5.1.6.
5.1.7.
Exit
1. Disconnect the AC cord from wall outlet.
Main item
Sub item
R-GAIN
G-GAIN
B-GAIN
R-CENT
G-RENT
B-CENT
Boot
STBY-SET
EMERGENCY
CLK MODE
CLOCK
Sample Data
8D
AE
FF
6C
80
A0
ROM
00
ON
00
FC7
8