Direct Wire Connection - Whirlpool HYBRIDCARE YWHD560CHW0 Installation Instructions Manual

Heat pump dryer
Table of Contents

Advertisement

2.
Connect neutral wire
Connect neutral wire (white or center) (C) of power supply cord
under center terminal block screw (B). Tighten screw.
3.
Connect remaining wires
Connect remaining wires under outer terminal block screws.
Tighten screws. Finally, reinsert tab of terminal block cover
into slot of dryer rear panel. Secure cover with hold-down
screw. Now, go to "Connect Outlet Hose."

Direct Wire Connection

B
C
Use 10 gauge copper wire.
Use a UL listed strain relief.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center
terminal.
Ground wire (green or bare wire) must be connected
to green ground connector.
Connect remaining 2 supply wires to remaining
2 terminals (gold).
Securely tighten all electrical connections.
Failure to do so can result in death, re, or
electrical shock.
Direct wire strain relief
1.
Attach direct wire strain relief
Unscrew the removable conduit connector (A) and any
screws from a 3/4" (19 mm) UL Listed strain relief (UL marking
on strain relief). Put the threaded section of the strain relief
(C) through the hole below the terminal block opening (B).
Reaching inside the terminal block opening, screw the
removable conduit connector (A) onto the strain relief threads,
and tighten securely.
Fire Hazard
A
B
C
11