8. Electrical Installation

STEP 1: Take the wire pair and connect to the breaker (see wiring diagram). Be sure that the
breaker is connected to one black wire and one red wire. Be sure the power to the unit is shut off
using the dedicated circuit breakers in the main electrical panel.
STEP 2: Run the correct set of power cable wires from the circuit breaker in the main electrical
panel to the water heater by utilizing a suitable wire gauge which meets all applicable electrical
codes for the size of the breaker. Then, connect the power cable to the block terminal within the
water heater.
STEP 3: Unit requires a ground conductor for the incoming circuit.
STEP 4:
DOUBLE CHECK the electrical connections and ensure the wire connections are
correct, tight and secure. It's important to confirm that the right breaker size and wire gauge has
been used and that the unit has been connected to a ground in accordance with applicable codes.
Be sure to reattach the front cover of the unit with two screws.
STEP 5: Ensure that all the air has been purged from the water lines before turning on power to
the unit. Refer to STEP 3 in the plumbing installation section. Restore power to the unit through
the dedicated circuit breaker in the main electrical panel.
It is crucial to follow the wire connection as shown and ensure all connections are made
correctly for proper operation of the unit. The unit will not operate correctly, even though it
turns on and otherwise appears to function, if you mix up one set of wire with another.
Electrical Specifications by Heater Input
Item #
BD-18-DWH
BD-24-DWH
BD-27-DWH
BD-29-DWH
BD-36-DWH
Power Rates
Item #
BD-18-DWH
BD-24-DWH
BD-27-DWH
BD-29-DWH
BD-36-DWH
Your tankless water heater is now installed and ready to use! Follow the General Operating
Instructions to complete the setup.
10
kW
Max
Required Breaker
Amps
18
75
2 x 40A Double Pole
24
100
3 x 40A Double Pole
27
112.5
3 x 40A Double Pole
29
120
3 x 40A Double Pole
36
150
4 x 40A Double Pole
240V
220V
18,000 Watts
15,125 Watts
24,000 Watts
20,166 Watts
27,000 Watts
22,687 Watts
29,000 Watts
24,368 Watts
36,000 Watts
30,250 Watts
Req. Wire Size
2 x 8/2 AWG with Ground
3 x 8/2 AWG with Ground
3 x 8/2 AWG with Ground
3 x 8/2 AWG with Ground
4 x 8/2 AWG with Ground
208V
13,520 Watts
18,026 Watts
20,280 Watts
21,782 Watts
27,040 Watts