GE GeoSpring GEH50DFEJS Owner's Manual page 12

Hybrid electric residential water heaters
Table of Contents

Advertisement

Anode Rod Maintenance and Service
CAUTION - IMPORTANT SAFETY NOTICE
This information is intended to use by individuals
possessing adequate background of electrical, electronic
a major appliance may result in personal injury and
property damage. The manufacturer or seller cannot be
responsible for the interpretation of this information, nor
can it assume any liability in connection with its use.
Tools needed:
• Slot Screwdriver
• Tape
• Socket Wrench
• 1
1
/
16
• Softset Sealant
• Anode Rod, if needed
* See page 24 for part ordering instructions
To service the Anode Rod:
1. Disconnect power, shut off the water supply, and partially
drain one or two gallons from the water heater through
the lower drain valve.
2. Remove the filter, trim ring, and front top cover as shown
in Illustration A.
Filter
Trim Ring
Front
Top Cover
Illustration A
3. Reinstall the trim ring, place a protective layer of tape on
sheet metal edges, as shown in Illustration B.
12
Trim Ring
Tape Process
Tube Pinch Off
Tape Corner
and Edges
Illustration B
4. If present, remove insulation to uncover the anode rod
as shown in Illustration C. Unplug anode wire (on some
models).
Wires
Anode Rod
Wires
Illustration C
5. Using a 1
1
/
16
rod, then lift out to inspect as shown in Illustration D.
Anode Rod
Illustration D
6. To install the anode rod, seal the threads with soft set
sealant, thread into the port and using the torque wrench
tighten to 50 ± 5 ft-lbs of torque. Plug in the wire for the
anode rod (some models). If an Aluminum-Zinc or other
non-sensing anode rod is installed, the anode depletion
sensing feature must be disabled and the wire end taped
(some models).
7. Turn water supply on, open a tap to remove any air in
plumbing system, inspect for leaks, then reassemble the
unit in reverse order as shown in Illustration A, and turn
the power on. Reset the ANODE button (some models)
by pressing and holding for 10 seconds to indicate that a
new anode depletion sensing anode rod is installed.
49-50300-2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents