6. Replace the seal cap and gasket and screw tightly closed;
7. Remove the pressure gauge and close the test point
pressure;
8. Prior to operation, test the gas pressure regulator for leaks.
B
D
E E . . 1 1 0 0
E E l l e e c c t t r r i i c c a a l l c c o o n n n n e e c c t t i i o o n n
E E . . 1 1 0 0 . . 1 1 E E l l e e c c t t r r i i c c a a l l a a p p p p l l i i a a n n c c e e s s
W W A A R R N N I I N N G G
Work on the electrical systems
must only be carried out by
specialised personnel.
Before connecting, make sure that:
• the mains voltage and frequency match those indicated on
the appliance data plate;
• there is an efficient earth contact;
• the power supply is arranged and able to take the actual
current absorption and that it is correctly executed accord-
ing to the regulations and provisions in force in the country
of use.
• a differential thermal-magnetic switch suitable for the input
specified on the dataplate, with contact gap enabling
complete disconnection in category III overvoltage condi-
tions and complying with the regulations in force, is installed
between the power cable and the electric line.
For the correct size of the switch, refer to the absorbed
current specified on the appliance dataplate.
To access the terminal board:
1. Remove the control knobs;
A
C
21
2. Unscrew the drain valves;
NOTE!
To unscrew the valves hold the pipe with a
special tool to prevent its rotation and possible
damage.
3. Removing the fixing screws;
4. Connect the power cable to the terminal block according to
the wiring diagram provided with the appliance (refer to B.5
N7E Electric appliance technical data );
5. Secure the power cable with the cable clamp.
I I M M P P O O R R T T A A N N T T
The manufacturer declines any liability if
the safety regulations are not respected.
E E . . 1 1 1 1
P P o o w w e e r r c c a a b b l l e e
Unless otherwise specified, our appliances are not equipped
with a power cable.
The installer must use a flexible cable having characteristics
not lower than the H07RN-F rubber insulated type.
Protect the section of cable outside the appliance with a metal
or rigid plastic tube.