WORKING RANGE

20
5
WORKING RANGE

5.1. POWER SUPPLY

Working Voltage
Voltage Imbalance
Starting Voltage
5.2. WORKING RANGE
Applicable models:
RAC-18WPB
RAC-25WPB
RAC-35WPB
RAC-50WPB
The temperature range is indicated in the following table.
Cooling
o
working range
min (
C)
outdoor
-10
indoor
16
Cooling working range
COOLING
50
40
30
20
10
0
-10
-20
-30
5 10 15 20 25 30 35 40 45 50
Indoor Temperature
207V ~ 253V
Within a 3% Deviation from Each Voltage at the Main Terminal of
Outdoor Unit
Higher than 85% of the Rated Voltage
o
o
max (
C)
rated (
C)
43
35
43
27
Heating
o
working range
min (
C)
outdoor
-15
indoor
16
Heating working range
HEATING
40
30
20
10
0
-10
-20
-30
0
5
10
15
Indoor Temperature
o
o
max (
C)
rated (
C)
21
7
26
20
20
25
30
35
40