Wiring Distance; Wiring Routes - Bosch Photobeam 5000 Installation And Operation Manual

Table of Contents

Advertisement

14
en | Wiring
4.2

Wiring distance

Refer to the table to determine the minimum wire gauge for a single sensor system (one
transmitter and one receiver). The distances specified are between the power source and the
last (farthest) unit on the single wire run. For multiple detector configurations, divide the wire
distance in the table by the number of systems in the configuration (1 system = 1 transmitter
and 1 receiver).
Wire Gauge
AWG
22
19
16
4.3

Wiring routes

Refer to the graphics below for wiring routes examples. The illustrations depict both one, and
two sets of detector systems on a single wire run.
The graphics below show simple examples of wiring concepts, depicting how to power the
transmitter and receiver pairs, and how to combine alarm outputs. Local regulatory
requirements and technical parameters specific to a connected control panel determine the
exact details of the wiring. Review local regulations and the connected control panels
technical documentation before planning wire routes and connections. Selecting the proper
wire routes and gauges depend on the number of devices, overall distance, and voltage drop
parameters for each individual device.
2016.02 | 03 | F.01U.303.478
Maximum wiring distance
ISC-FPB1-W60QF
Ø mm 12V
24V
0.65
90 m
820 m
(295 ft)
(2690 ft)
0.90
170 m
1600 m
(557 ft)
(5249 ft)
1.29
320 m
2930 m
(1049 ft)
(9612 ft)
Installation and Operation Guide
Available from A1 Security Cameras
www.a1securitycameras.com email: sales@a1securitycameras.com
ISC-FPB1-W120QF
ISC-FPB1-W200QF
12V
24V
12V
80 m
790 m
80 m
(262 ft)
(2591 ft)
(262 ft)
170 m
1550 m
160 m
(557 ft)
(5085 ft)
(524 ft)
310 m
2830 m
300 m
(1017 ft)
(9284 ft)
(984 ft)
Photobeam 5000
24V
770 m
(2526 ft)
1500 m
(4921 ft)
2740 m
(8989 ft)
Bosch Security Systems, Inc.