Mitsubishi Electric Mr.SLIM PLA-RP50EA Service Manual page 28

Split-type, heat pump air conditioners
Hide thumbs Also See for Mr.SLIM PLA-RP50EA:
Table of Contents

Advertisement

9-6. HOW TO CHECK THE PARTS
PLA-RP35EA.UK
PLA-RP71EA.UK
Parts name
Room temperature
thermistor (TH1)
Pipe temperature
thermistor/liquid (TH2)
Condenser/evaporator
temperature thermistor (TH5)
Vane motor (MV)
White
M
Orange
Red
Blue
Yellow
Drain pump (DP)
1 Check if the drain float switch works properly.
2 Check if the drain pump works and drains water properly in cooling operation.
1
Red
3 If no water drains, confirm that the check code P5 will not be displayed 10 minutes after the
Purple
2
Black
3
Note: The drain pump for this model is driven by the internal DC motor of controller board, so it is not
Normal
Red–Black: Input 13 V DC → The motor starts to rotate.
Purple–Black: Abnormal (check code P5) if it outputs 0–13 V square wave (5 pulses/rotation), and
Drain float switch (FS)
Measure the resistance between the terminals with a tester.
Moving part
1
2
3
4
i-see Sensor (Option)
Turn the power ON while the i-see Sensor connector is connected to the CN4Z on indoor
controller board. A communication between the indoor controller board and i-see Sensor
board is made to detect the connection.
Normal: When the operation starts, the motor for i-see Sensor is driven to rotate the i-see Sensor.
Abnormal: The motor for i-see Sensor is not driven when the operation starts.
Note: The voltage between the terminals cannot be measured accurately since it is pulse output.
1 2 3 4
1 2 3 4
i-see Sensor motor
(Option)
White
M
Orange
Red
Yellow
Blue
OCH626
PLA-RP50EA.UK
PLA-RP100EA.UK
Measure the resistance with a tester.
(Parts temperature 10 to 30°C)
Normal
4.3 to 9.6 k"
Refer to "9-6-1 Thermister".
Measure the resistance between the terminals with a tester.
(At the ambient temperature 20 to 30°C)
Connector
Red–Yellow (5–3, 0–8, 5–3, )–8)
Red–Blue (5–1, 0–6, 5–1, )–6)
Red–Orange (5–4, 0–9, 5–4, )–9)
Red–White (5–2, 0–7, 5–2, )–7)
operation starts.
possible to measure the resistance between the terminals.
the number of rotation is not normal.
State of moving part
Normal
UP
Short
DOWN
Open
Measure the resistance between the terminals with a tester.
(At the ambient temperature 20 to 30°C)
Normal
Red–Yellow
Red–Blue
250 "
PLA-RP60EA.UK
PLA-RP125EA.UK
Check method and criterion
Abnormal
Opened or short-circuited
Normal
300 "
Abnormal
Other than short
Other than open
Red–Orange
Red–White
28
PLA-RP140EA.UK
Abnormal
Open or short
Switch
Magnet
Moving
Part
Abnormal
Open or short

Advertisement

Table of Contents
loading

Table of Contents