Step 7 - Sanitize, Test and Purge System
PRESSURE TEST THE SYSTEM
Note: Complete the sanitizing procedures on the pre-
ceding page before pressure testing.
To pressure test the system, complete the following steps.
1. Open the water supply valve to the Reverse Osmosis
System. See Fig. 24.
2. Open the main water supply valve and several house
faucets. This will purge air from the house plumbing
and system. Close faucets when water runs smooth.
See Fig. 24.
3. Pressure will start to build in the RO system in about 2
hours Carefully check all fittings and connections as
the system builds pressure. Check for water leaks. Fix
leaks if any are found. If problems exist, refer to the
troubleshooting chart or call the toll free number. (See
number below)
Note: When the system is first pressurized, water
may ''spurt'' from the faucet air gap hole until air is
expelled from the RO system.
Please review the following operating features before
using your Reverse Osmosis System:
You will not have filtered water immediately. It may
take 1-3 hours to completely fill the storage tank and
create maximum flow from the Reverse Osmosis
faucet.
Water Pressure from the Reverse Osmosis faucet will be
less than your standard faucet.
Water will run to the drain while the Reverse Osmosis
system is producing water, even if you are not drawing
water from the Reverse Osmosis faucet. You may hear
a small quantity of water going to the drain for a couple
of hours. Water going to the drain will automatically
shut off when the storage tank is full.
PURGING THE SYSTEM
To purge the system, complete the following steps.
1. Open the Reverse Osmosis Faucet and let water
through the system for a 24 hour period.
Note: Water flow will be a slow trickle at this time.
2. Close the Reverse Osmosis faucet after the 24 hour
purging period is complete.
3. When the purging is finished, your Reverse Osmosis
system is ready for use.
Questions? Visit www.ecodyne.org or call Toll Free 1-866-986-3223
Kitchen
faucet
Storage
Tank
17
Reverse
Osmosis
Faucet
HOT COLD
Shutoff Valve
Water supply Shutoff
Valve to Reverse
Osmosis System
FIG. 24