3. Unscrew the screw and slowly pull
out the burner.
4. Release the burner injector with a 7
mm socket spanner and replace it
with a right one.
Assemble the burner in a revers
sequence.
Replace the gas type sticker near the gas
supply ramp with the one related to the
new gas type.
14.13 Adjusting the minimum
gas level on the oven burner
1. Disconnect the appliance from the
electricity.
A
B
1
2
2. Remove the knob for the oven
functions. If there is no access to the
bypass screw dismount the control
panel before adjustment start.
3. With a thin and flat screwdriver adjust
the bypass screw A.
The model determines the position
of the bypass screw A.
Changing from natural gas to
liquid gas
1. Fully tighten the bypass screw.
2. Put the knob back.
3. Connect the appliance to the
electricity.
Changing from liquid gas to
natural gas
1. Unscrew approximately one turn the
bypass screw position A.
2. Put the knob for the oven functions
back.
3. Connect the appliance to the
electricity.
WARNING!
Put the mains plug into
the mains socket only if
all parts are back into
their initial position.
There is a risk of injury.
4. Light the burner.
Refer to "Oven - Daily use" chapter.
5. Turn the knob for the oven functions
on the minimum position.
6. Remove the knob for the oven
functions again.