2-3.

SERVO SYSTEM CHECK

Unless otherwise specified, set the switches to the following
positions.
CHANNEL
switch ..................................................... LINE
TAPE SPEED
switch ......................................................... SP

2-3-1. RF Switching Position Adjustment

(MA-286, RP-217 Boards)

[Adjustment Purpose]
To adjust the link of the A-ch and B-ch of the tape playback outputs.
To make the unit compatible with other tapes and units. If this
specification is not satisfied, the link will appear on the screen and
the screen will be disrupted, etc.
Mode
Playback
Signal
Alignment tape: SP color bar portion
Measurement point
CH1: Video LINE OUT (EURO)
CH2: CN261 pin 2 (RF SWP)
Measuring instrument
Oscilloscope
6.5 ± 0.5H (416 ± 32 µsec)
Specified value
[Adjustment Method]
1) Short-circuit between CN261 pin 5 and pin 3 on RP-217
board for about 1 second to activate the RF switching position
adjustment mode.
2) Check that "ADJ-RF" is indicated on FL display.
3) Using the channel + and – buttons, adjust to 416 ± 32µsec (6.5
± 0.5H).
4) Press the PAUSE button.
5) Press the EJECT button.
Fig. 7-2-3.
2-4.

VIDEO SYSTEM CHECKS AND ADJUSTMENT

For the video system checks, follow the checking procedures given
below as a rule. The color bar video signal supplied from the pattern
generator is used as the video input signal for the video system
adjustment of the recording mode. Check that the signal satisfies
the specified value designated in the "Check of input signal" (Fig.
7-2-2)
Unless otherwise specified, set the switches to the following
positions.
CHANNEL
switch .................................................. LINE 1
TAPE SPEED
switch ......................................................... SP
[Checking Sequence]
1) X'tal OSC Check
2) SYNC AGC Check
3) White clip/Dark clip Check
4) Recording Y Level Check
5) Recording Chroma Level Check
6) Playback Level Check
7) VCO frequency adjustment

2-4-1. X'tal OSC Check (MA-286 Board)

Mode
Signal
Measurement point
Measuring instrument
Specified value
Note: A frequency counter should be connected through a buffer
amplifier (oscilloscope, etc.) having a high impedance and
a low capacitance.
[Check Method]
1) Check that the oscillation frequency satisfies the specified value
and that the oscillation voltage is 500 ± 200mVp-p.
4,443,619 ± 90Hz
7-3
Playback
Alignment tape: SP Color bar portion
IC201 pin %•
Oscilloscope and Frequency counter
4,433,619 ± 96Hz
500 ± 200mVp-p
Fig. 7-2-4.