Incorrect handling might cause the inverter option to operate improperly, its life to be reduced considerably, or at the
worst, the inverter option to be damaged. Handle the power regeneration common converter properly in accordance
with the information in each section as well as the precautions and instructions of this manual to use it correctly.
This manual is written for the power regeneration common converter FR-CV.
For handling information on the inverter, stand-alone options, etc., refer to the corresponding manuals.
(1) Unpacking and product check
Unpack the power regeneration common converter and check the capacity plate on the front cover and the rating
plate on the inverter side face to ensure that the product agrees with your order and the inverter is intact.
1)
Definition of the power regeneration common converter type
FR-CV-
Symbol
None
H
Capactiy plate
Rating plate
2)
The power regeneration common converter accessory
Instruction manual
3)
Definition of the dedicated stand-alone reactor
Remember to prepare the dedicated stand-alone reactor as it must be installed.
FR-CVL-
Symbol
Voltage class
None
200V class
H
400V class
Capacity plate
If you have found any discrepancy, damage, etc., please contact your sales representative.
(2) Confirmation of the peripheral device types
The dedicated stand-alone reactor must be installed.
Power regeneration common converter
FR-CV-7.5K(-AT)
FR-CV-11K(-AT)
FR-CV-15K(-AT)
FR-CV-22K(-AT)
FR-CV-30K(-AT)
FR-CV-37K
FR-CV-55K
Note: 400Vclass devices have capacity numbers preceded by H in their type codes.
K-
Voltage class
Symbol
200V class
7.5 to 55
400V class
Capacity plate
FR-CV-11K
Converter type
Serial number
K
Symbol
7.5 to 55
Applicable Inverter
Symbol
Capacity
None
Indicates capacity
AT
in "kW".
MITSUBISHI
MODEL
Input rating
INPUT
Output rating
OUTPUT :
Serial number
SERIAL :
Applicable Converter
Capacity
Indicates capacity
in "kW".
Dedicated stand-alone reactor (required)
FR-CVL-7.5K
FR-CVL-11K
FR-CVL-15K
FR-CVL-22K
FR-CVL-30K
FR-CVL-37K
FR-CVL-55K
2
Structure
Heat sink outside mounting structure
Enclosure inside installation structure
Rating plate
INVERTER
FR-CV-11K
:
XXXXX
XXXXX
PASSED
Capacity plate
FR-CVL-11K
Reactor type
Converter
type