Summary of Contents for AEG DI 8610

  • Page 1 DI 8610 Dunstabzugshaube Afzuigkap Hotte aspirante Cooker Hood Cappa aspirante Montage- und Gebrauchsanweisung Installatie- en gebruiksaanwijzing Manuel de montage et d’utilisation Operating and Installation Instructions Istruzioni di montaggio ed uso...
  • Page 2 Printed on recycled paper AEG - putting words into action...
  • Page 3: Table Of Contents

    Contents Safety warnings for user for kitchen unit installer Introduction Extractor version Filter version Hood Operation Control device for grease and activated charcoal filters Grease filter LED (D) Activated charcoal filter LED (E) Resetting the saturation indicator Maintenance and care Metal grease filter Open the metal grease filter Carbon filter...
  • Page 4: Safety Warnings

    Safety warnings for user • Always cover lighted elements, to prevent excess heat from damaging the appliance. In the case of oil, gas and coal fired cookers it is essential to avoid open flames. • Also, when frying, keep the deep frying pan on the cooker top/ cooker under careful control.
  • Page 5 • It is advisable to apply for authorization from the relevant controlling authority when connecting the outlet to an unused chimney flue or combustion gas duct. The air outlet installation must comply with the regulations laid down by the relevant authorities. •...
  • Page 6: Introduction

    • The hood is supplied as an extractor unit and can also be used with a filtering function by fitting one activated carbon filter (special accessory). • You will need original AEG carbon filter for this function (see Special Accessories). • The air is discharged to the outside through a pipe, which must be fitted to connection flange A.
  • Page 7: Filter Version

    • When the hood is used in the filter version it must be fitted with an original AEG KF20 activated charcoal filter (see Special accessories). • Fix the deflector using 4 screws Ø 3.5x6.5 mm. Fig. 2.
  • Page 8: Hood Operation

    Hood Operation • Best results are obtained by using a low speed for normal conditions and high speed when odours are more concentrated. Turn the hood on a few minutes before you start cooking then you will get an underpressure in the kitchen. It should be left on after cooking for about 15 minutes or until all odours have disappeared.
  • Page 9: Control Device For Grease And Activated Charcoal Filters

    Control device for grease and activated charcoal filters This hood is fitted with a device that signals when it is necessary to clean the grease filter or the activated charcoal filter (in the case of recirculation version with activated charcoal filter). On delivery, the hood is not supplied with an activated charcoal filter, so the saturation indicator will be disabled.
  • Page 10: Maintenance And Care

    Maintenance and care • The hood must always be disconnected from the mains power supply before beginning any maintenance work. Metal grease filter • The purpose of the grease filters is to aspirate grease particles which form during cooking and it must always be used, either in the external evacuation or internal recycling function.
  • Page 11: Carbon Filter

    • The activated carbon filter should only be used if you want to use the hood in its filtering function. • To do this you will need an original AEG activated carbon filter (see special accessories). • Cleaning/replacing the carbon filter Unlike other carbon filters, the LONGLIFE carbon filter can be cleaned and reactivated.
  • Page 12: Changing The Light Bulb

    Warning • Failure to observe the instructions on cleaning the unit and changing the filters will cause a fire hazard. You are therefore strongly recommended to follow these instructions. • The manufacturer declines all responsibility for any damage to the motor or any fire damage linked to inappropriate maintenance or failure to observe the above safety recommendations.
  • Page 13: Cleaning

    Cleaning • Warning: always disconnect the hood from the mains power supply before cleaning it. Never insert pointed objects in the motor’s protective grid. • Wash the outside surfaces using a delicate detergent solution. Never use caustic detergents or abrasive brushes or powders. •...
  • Page 14: Guarantee Conditions

    Guarantee conditions Guarantee Conditions AEG offer the following guarantee to the first purchaser of this appliance. 1. The guarantee is valid for 12 months commencing when the appliance is handed over to the first retail purchaser, which must be verified by purchase invoice or similar documentation.The guarantee does not...
  • Page 15 Before you move please contact your nearest Customer Care Centre, listed below, to give them details of your new home.They will then ensure that the local Service Organisation is aware of your move and able to look after you and your appliances. France Senlis Germany...
  • Page 16: Technic Details

    Technic Details Dimensions: Height x Width x Depht (in cm) Maximum absorbed power: Motor absorption: Lighting: Length of the cable: Mounting accessories included 1 Deflector 6 Wood-screws 6 x 70 mm 6 Wall plugs Ø 10 mm 10 Nuts 8 Metal-screw 3 x 9 mm 14 Metal-screw 4 x 8 mm 10 Metal-screw 4 x 7 mm 80-106,5 x 100 x 65...
  • Page 17: Electrical Connection

    Electrical connection Safety warnings for the electrician Before connecting the appliance to the power supply, check that the voltage indicated on the rating plate corresponds to the mains power supply available. Appliances fitted with a plug can be connected to any standard power socket within easy access.
  • Page 18: Installation

    Installation - Fig. 6-7-8 Expansion plugs are provided to secure the hood to most types of ceilings. However, a qualified technician must verify suitability of the materials in accordance with the type of ceiling. The ceiling must be strong enough to take the weight of the hood. During electrical connection ensure the power supply is disconnected at the domestic main switch.
  • Page 19 Fig. 6...
  • Page 20 • Fit the nuts with fixing hooks (14) supplied inside the top and bottom sections of the flues at the rectangular slots. A total of 10 nuts must be fitted. • Join the two top sections of the flue to cover the truss (15) so that one of the slots on the sections is situated on the same side of the control panel and the other on the opposite side.
  • Page 21 Fig. 7...
  • Page 22 covers the motor compartment and electrical connection box, then ensure it from inside the hood using two screws (19). • Apply the 2 tabs (20 - supplied) to cover the fixing points of the bottom flue (CAUTION! THE BOTTOM FLUE TABS ARE THE NARROWER AND SHALLOWER ONES).
  • Page 23 Fig. 8...

Table of Contents