Panasonic Aquarea WH-ADC0309J3E5 Planning And Installation Manual page 204

Air-to-water heat pumps
Hide thumbs Also See for Aquarea WH-ADC0309J3E5:
Table of Contents

Advertisement

Appendix
8
204
Menus
For user
Menu
1.2
Holiday timer
To save energy, a holiday
period may be set to either turn
OFF the system or lower the
temperature during the period�
• Weekly timer setting may be temporarily disabled during Holiday timer setting
but it will be restored once the Holiday timer is completed�
1.3
Quiet timer
To operate quietly during the
preset period�
6 patterns may be set�
Level 0 means the mode is off�
1.4
Room heater
To set the room heater ON or
OFF�
1.5
Tank heater
To set the tank heater ON or
OFF�
1.6
Sterilization
To set the auto sterilization ON
or OFF�
• Do not use the system during sterilization in order to prevent scalding with hot water, or overheating of shower�
• Ask an authorised dealer to determine the level of sterilization function field settings according to the local laws and
regulations�
1.7
DHW mode (Domestic Hot Water)
To set the DHW mode to
Standard or Smart�
• Standard mode have faster
DHW Tank heat up time�
Meanwhile Smart mode
take longer time to heat up
DHW time with lower energy
consumption�
To set the tank sensor to Top
or Center�
• Selection of the tank sensor
to top slow down the start of
boiling up the tank and reduce
power consumption�
Please change this selection
to "Center" when the hot water
becomes insufficient.
Aquarea air-to-water heat pumps - Planning and installation manual - 02/2022
Default Setting
Setting Options / Display
OFF
ON
Holiday start and end�
Date and time
OFF or lowered temperature
Time to start Quiet :
Date and time
Level of quietness:
0 ~ 3
OFF
OFF
ON
Standard
Top
EN
21