4-2. TEST MODE

Data display mode
How to enter:
After turning on the dryer, press Drylevel
mode.
To change the mode, use the cycle selector.
1 Main micom version
4 Option value
Temperature data for detecting
7
if the vent is clogged
Error Recall
Error Recall mode reminds users of the last error that was detected. Press and hold both the
and Dry Level buttons for 8 seconds to enter this mode. In Error Recall mode, the last error
that was detected appears. If no error has been found, nothing is displayed.
Smart Install
Smart Install allows service personnel to check if the dryer is installed properly.
To enter Smart Install
Turn on the dryer, and press and hold the Adjust
A message of "SC" appears.
Step 1.
Check the touch sensor
Enter Smart Install mode, and open the door. The state of the touch sensor appears.
- 0 : Touch sensor open
- 1 : Touch sensor short
Put a wet cloth on the touch sensor to display
Check the motor and heater
Step 2.
Press the Start button to enter the diagnosis mode. The diagnosis result appears.
- OK : Both motor and heater work normally
- HC : Motor or heater doesn't work normally
Time
Temp
Display mode number
2 Display micom version
5 Temperature data
Average touch sensor data for
8
1 minute
Time Up + Temp buttons for 7 seconds.
"1" . Removing the cloth displays "0" .
Time within 2 seconds to enter the display
3 Touch-sensitive module version
Average temperature data for
6
1 minute
9 Cycle count