Problem Areas
1.17 Ambient Light Sensor
1.17.1 Light Sensor malfunctions
Check:
Inspect the Light Sensor window on the Cover Front
Housing Display Assy.
Action:
If clogged – clean it..
Check:
Inspect the light sensor on the Cover Front Housing Display
Assy.
Action:
1. If dirty – clean it.
2. If scratched or damaged – replace the Cover Front
Housing Display Assy.
Check:
Inspect the Bracket Proximity Sensor on the Main PBA.
Action:
1. If clogged – clean it.
2. If not properly assembled – disassembly and reassembly.
1265-6294 Rev 4
© Sony Mobile Communications AB – Company Internal
Troubleshooting Guide (mech)