BASIC OPERATING/MAINTENANCE
INSTRUCTIONS
• Make sure power is supplied to the pump (circuit breaker is on, GFCI is
set, pump is "plugged in").
• Fill the tub with water-- at a minimum to a level above the highest
jet. In the case of some manufacturer's specifications, fill water to the
low water level sensor indicator.
• To turn pump on, depress airswitch button OR depress on/off button
on keypad OR turn on wall timer. Please refer to tub manufacturer's
user manual to determine your specific design of tub or spa unit). If AT
model pump, the time will set automatically.
• To turn unit off, depress airswitch button OR depress on/off button on
keypad OR turn off wall timer.
• The pump/motor assembly does not require maintenance. However,
the tub and pump should be checked semi-annually for leakage of any
kind.
• The electric motor uses sealed grease bearings, which do not require
additional lubrication. The pump should not be run dry (without
water). If this occurs, check the pump for leaks. Under normal
conditions the bath/spa water will lubricate and cool the seal assembly
while running.
• If the whirlpool tub will be stored during freezing weather, it is
suggested that the tub (jets, piping, and pump) be completely free of
water to avoid damage from the freezing.
• We DO NOT recommend using sudsing oil or bubble bath during a
whirlpool session. The agitation will create an overflow of bubbles.
• Follow tub manufacturer's recommendation for periodic cleaning
of the whirlpool tub system. For whirlpool tubs, a low-foaming
dishwasher detergent with 4 to 6 ounces of household bleach can be
added to a full tub of water. Run the tub for approximately 10 minutes
and drain. Fill the tub with clean, cool water, and run for 10 minutes
and drain.
TROUBLESHOOTING GUIDE
PUMP DOES NOT RUN
POSSIBLE CAUSES:
• No power to pump
- check incoming power to pump
- is circuit breaker on?
- is GFCI operating properly?
- is pump plugged in?
• Airswitch disconnected
- is airswitch hose connected to pump?
- is airswitch hose connected to actuator button
on tub deck?
PUMP NOT PUMPING PROPERLY
POSSIBLE CAUSES:
• Blockage or leak
- jets should be pointed away from suction inlet
so air is not forced into pump suction
- is tub suction inlet blocked or covered?
- is there any debris in pump housing?
- is there a leak in the piping or the pump?
• Low voltage
- is the proper voltage applied to the pump?
- is there an extension cord being used?
2200 East Sturgis Road, Oxnard, CA 93030 • Ph. (805) 981-0262 • Fax (805) 981-9403
www.waterwayplastics.com • waterway@waterwayplastics.com
© 2010 Waterway Plastics
GENESIS GENERATION
BATH PUMPS
MODELS:
WW050
WW075
WW100
WW150
WARNING:
To reduce the risks of injury, do not allow children to use
this product unless they are supervised at all times.
WARNING:
Pump suction inlet should be installed with a
certified safety suction inlet and cover that does not exceed the
maximum flow rating of the installed pump and system. Failure to
provide for a properly rated suction assembly can case bodily injury,
disembowelment, and drowning from hair entrapment.
OWNER/OPERATOR
INSTRUCTION MANUAL
2200 East Sturgis Road, Oxnard, CA 93030 • Ph. (805) 981-0262 • Fax (805) 981-9403
www.waterwayplastics.com • waterway@waterwayplastics.com
810-0227.0410
© 2010 Waterway Plastics
810-0227.0410

Advertisement

loading

Summary of Contents for Waterway WW050

  • Page 1 2200 East Sturgis Road, Oxnard, CA 93030 • Ph. (805) 981-0262 • Fax (805) 981-9403 2200 East Sturgis Road, Oxnard, CA 93030 • Ph. (805) 981-0262 • Fax (805) 981-9403 www.waterwayplastics.com • waterway@waterwayplastics.com www.waterwayplastics.com • waterway@waterwayplastics.com 810-0227.0410 810-0227.0410 © 2010 Waterway Plastics © 2010 Waterway Plastics...
  • Page 2 IMPORTANT SAFETY INSTALLATION INSTRUCTIONS ELECTRICAL WIRING INSTRUCTIONS INSTRUCTIONS INSTRUCTIONS PERTAINING TO A RISK OF FIRE, ELECTRIC GENERAL INFORMATION The actual pump may be supplied with no cord, a three-wire cord with plug (-C), or a three-wire cord with leads for hard wiring to a junction box (-CC). This pump is intended solely for use with hydromassage bath tub (whirlpool bath) SHOCK, OR INJURY TO PERSONS applications.

This manual is also suitable for:

Ww075Ww100Ww150