Battery Alm XX
Proc1 Vccp AlmXX
Proc2 Vccp AlmXX
BB FSBvtt Alm XX
BB DIMMvtt AlmXX
BB +1.2v Alm XX
BB +1.5v Alm XX
BB +1.8v Alm XX
BB +3.3v Alm XX
BB +5v Alm XX
BB +1.2vs Alm XX
BB +1.5vs Alm XX
BB +1.25vs AlmXX
BB +3.3vs Alm XX
BB +5vs Alm XX
BB +12vs Alm XX
Virtual LCD indications when STATUS lamp is flashing amber
On-screen message
Mem Reconfigured
Mem Err Disable
CPU Reconfigured
E-Keying Error
Location Error
Description
A battery voltage alarm was
detected.
XX=09: Upper limit alarm
XX=02: Lower limit alarm
A voltage alarm was detected.
XX=09: Upper limit alarm
XX=02: Lower limit alarm
Description
The memory is degraded.
Correctable memory error frequently
occurs.
The CPU is degraded.
In the Blade Enclosure, combination
of installation locations of CPU
blade, mezzanine card, and switch
module is not correct. Thus, an
unconformity of interface signal was
detected and the CPU blade failed
to power on.
In the Blade Enclosure, the
installation location of CPU blade is
incorrect, or the installation locations
of the fan and CPU blade are
incorrect. Thus, the CPU blade
failed to power on.
General Description 2-11
Action
1. Check the installation status of
the battery.
2. Replace the battery.
Replace the CPU blade.
Action
1. Check the installation status of
the DIMM.
2. Replace the DIMM.
1. Check the installation status of
the CPU.
2. Replace the CPU.
Refer to the User's Guide of the
Blade Enclosure for the correct
installation locations.
Refer to the User's Guide of the
Blade Enclosure to check if the CPU
blade is installed in the correct
location.
Check the installation locations of
the fan and CPU blade.