THE FOLLOWING ARE CAUTIONARY STATEMENTS THAT MUST BE READ AND FOLLOWED
WARNING: Raritan Engineering Company, Inc. recommends that a qualified person or electrician install this
product. Equipment damage, injury to personnel or death could result from improper installation.
Raritan Engineering Company, Inc. accepts no responsibility or liability for damage to equipment,
or injury or death to personnel that may result from improper installation or operation of this
product.
WARNING: HAZARD OF SHOCK AND FIRE - Always use recommended fuse/circuit breaker and wire size.
WARNING: HAZARD OF FLOODING - Always shut off seacocks before leaving boat unattended.
WARNING: The electro scan operates on an Electrochemical principle. Introduction of any substance other than
salt water, human waste, Raritan Concentrate, Raritan C.P. or toilet tissue may cause heat build up
and extensive damage. If any other substance is introduced by accident, the electro scan must not
be turned on until entire system is flushed out with water.
electro scan with control
electro scan™ is a U. S. Coast Guard Certified Type I Marine Sanitation Device for use on inspected and
uninspected vessels 65 feet (19.7 Meters) and under. It must be operated within areas that are not declared
a Federal No Discharge Zone (NDZ) by the U.S. Environmental Protection Agency (EPA). This is
applicable for all U.S. territorial waters inside the three mile limit. Other countries - check with local
authorities.
electro scan is designed for recreational use and accommodates most marine toilets* it can be used with one
or, in some cases, two toilets. The electro scan is available in 12, 24 or 32 V DC.
The system consists of a Control Unit, LCD Display, System Status Panel and Treatment Tank. A salt feed
system (optional) must be utilized if operating in fresh or brackish water.
for use with the VacuFlush
*
VacuFlush
is a registered trademark of Sealand Technology, Inc.
®
Lectra/San
®
is a trademark of Exceltec. electroscan
Models EST12, EST24 and EST32
Installation and Maintenance Instructions
DURING BOTH INSTALLATION AND OPERATION
Double clamp all hose fittings below the waterline, check hose clamps frequently for integrity.
marine toilet manufactured by Sealand Technology, Inc., (See Application note L286)
®
is a trademark of Raritan Engineering Co., Inc., patent pending
optional salt feed systems
2 gallon tank
1
4 gallon tank

Advertisement

Table of Contents
loading

Summary of Contents for Raritan Electro Scan EST12

  • Page 1 WARNING: The electro scan operates on an Electrochemical principle. Introduction of any substance other than salt water, human waste, Raritan Concentrate, Raritan C.P. or toilet tissue may cause heat build up and extensive damage. If any other substance is introduced by accident, the electro scan must not be turned on until entire system is flushed out with water.
  • Page 2: System Status Panel

    (depends on installation chosen) Single Button operation - Both toilet and electro scan are operated by one of the System Status Panel LCD Display following options: Option #1: System status panel Touch Pad electro scan "Start/Stop" button activates both the toilet and READY TO FLUSH treatment cycle.
  • Page 3: Control Unit

    The electro scan has four basic components: Control Unit System Status Panel - Begins treatment cycle • and if wired flushes an electric toilet at the same RARITAN time. LECTRA/SAN Control Unit – Serves as the system’s central • LST / MC II control.
  • Page 4 POS FUSE BLOWN POS FUSE BLOWN POS FUSE BLOWN POS FUSE BLOWN POS FUSE BLOWN some external short, check toilet solenoid type, wiring to solenoid. Solenoid (relay) to toilet must be isolated coil type or Raritan *****ERROR***** *****ERROR***** *****ERROR***** *****ERROR***** *****ERROR*****...
  • Page 5 These will cause damage to treatment system. C.P. is the only toilet bowl cleaner recommended by Raritan. Using Raritan's C.P. Cleans Potties, a bio-enzymatic toilet bowl cleaner, will keep the bowl clean and fresh smelling and won't damage the treatment system.
  • Page 6 IMPORTANT • Improper winter lay up is a major cause of failure due to freezing or buildup. Steps 1. Flush toilet and activate electro scan several times to clean out hoses and tank. 2. Turn off water supply and flush toilet as dry as possible.
  • Page 7 U.S.C.G. Type I MSD Certification #159.015/0107/1 Maximum Roll/Pitch Angle: 30° Capacity: 575 Gallons Per Day Maximum Temperature Exposure: 120° F (49° C) Maximum Total Flush Volume: 1.5 gallons/flush (5.7 liters/flush) Maximum cable length for LCD Dispaly: 16' (5M) Maximum cable length system status panel: 25' (7.6M) NOTES FOR WIRING: i n i l i f...
  • Page 8 1 1/2" NPT Intake Plug • PVC Cement • ° 1 1/2" slip PVC fitting • 1 1/2" (3.8 mm) I.D. sanitation hose (raritan part # SH) • Treatment tank • Hose clamps • system status panel, control unit, LCD display, cables •...
  • Page 9 NOTE: Future access to control box is imperative. If unit is installed in an area where access will be difficult contact Black Raritan for instructions on mounting the control box for Orange White distance more than two feet.
  • Page 10 Both toilet and electro scan are operated by one of the following options: NOTES: • Use only a solenoid/relay with an isolated coil Raritan part number CDS* (*specify voltage) Option #1 • Connect only the solenoid/relay (CDS) coil to toilet 1 or 2 quick connect.
  • Page 11 F LU SH TIM E FLUSH CONTROL EX TEND FL USH L S T PAN EL FROM FLUSH TIME 1 2 3 1 2 3 RARITAN RARITAN FUSES HD NEG HD POS FUSES HD NEG HD POS To other SALT FD + EXT TRIG...
  • Page 12 This page left blank...
  • Page 13: Microprocessor Board

    • Odor permeating through hose or connections Rub damp rag on hose, if odor transfers to rag hose needs to be replaced with high quality sanitation hose Raritan part # SH • Treatment unit is leaking Follow discharge hose from toilet to tank, check area around motors too •...
  • Page 14 31-702 31-705 31-113-2 32-101AW, 33-101AW or 34-101AW 32-102A, 33-102A, or 34-102A ETB2 31-104C 31-105 32-700, 33-700, or 34-700 31-102 31-120 31-134 31-121 31-101W 31-103 31-106 31-106 31-103 31-107 31-110-2 31-108 31-109 31-112 31-110-2 31-110-1 31-110-1 32-5000, 33-5000 or 34-5000 31-121 31-122 31-114 31-121...
  • Page 15 TREATMENT UNIT CONTROL Part No. Description Part No. Description 31-618 Cable for LCD and System Status Panel 32-102A** Mixer Motor 2 1/2'' Dia. 12 VDC (not shown) 33-102A** Mixer Motor 2 1/2'' Dia. 24 VDC 31-702 LCD Display 34-102A** Mixer Motor 2 1/2" Dia. 32 VDC 31-705 System Status Panel 31-121...
  • Page 16: Limited Warranty

    1. TO OBTAIN WARRANTY SERVICE, Consumer must deliver the product prepaid, together with a detailed description of the problem, to Raritan at 530 Orange St., Millville, N.J. 08332, or 3101 SW 2nd Ave. Ft. Lauderdale, FL 33315. When requesting warranty service, purchaser must present a sales slip or other document which establishes proof of purchase. THE RETURN OF THE OWNER REGISTRATION CARD IS NOT A CONDITION PRECEDENT OF WARRANTY COVERAGE.

This manual is also suitable for:

Electro scan est24Electro scan est32

Table of Contents