Safire KIT-BODYTEMP-BLACKBODY User Manual

Thermal imaging body temperature measurement system

Advertisement

Quick Links

Thermal Imaging Body Temperature
Measurement System
(KIT-BODYTEMP-BLACKBODY)
User Manual
1

Advertisement

Table of Contents
loading

Summary of Contents for Safire KIT-BODYTEMP-BLACKBODY

  • Page 1 Thermal Imaging Body Temperature Measurement System (KIT-BODYTEMP-BLACKBODY) User Manual...
  • Page 2: Table Of Contents

    CONTENTS Notice...............................3 Features............................3 Product Specification Thermal camera................... 3 Installation............................4 4.1 Cables and Interfaces........................ 4 4.2 System Installation........................5 System configuration........................6 5.1 Device Management........................6 5.2 Referential point setting......................8 5.3 Thermal/Visible camera view field matching................8 5.4 Smart (Face detection) Temperature Measurement Setting............9 5.5 Alarm setting...........................
  • Page 3: Notice

    1 Notice Try to keep Blackbody and Thermal Camera at the same height, make sure the Blackbody won’t be  sheltered by people or other objects; Try to position the Blackbody on a corner of the thermal image; To decrease sunshine’s affection on temperature measurement, avoid installation outside or in ...
  • Page 4: Installation

    Temp.Calibration ≤±0.2°C Accuracy Temperature Measurement Object Temp. Range 20°C~50°C Accuracy <±0.3°C Temp.Calibration Build-in/Outlaid blackbody, automatically calibration Housing IP grade IP66 Interface 1x RJ45 for Ethernet, 1x 12V power supply Software Temp.Measurement Smart detection, face capture, tracking and body temp. correction; Alarm/Capture 3 grades’...
  • Page 5: System Installation

    4.2 System Installation 4.2.1 Camera Installation Fix camera’s holder by crew, install the camera (on wall or other support) in a proper height (recommend height at approx.2m); Power supply with adapter (manufacturer supplied): AC 220V; 4.2.2 Blackbody Installation Tripod Setting Take off the adapter block from tripod;...
  • Page 6: System Configuration

    System configuration Device Management Add Thermal Imaging Camera on System Tools via Device Management Interface: STEP 1: Add the thermal camera Please refer to the figure picture, choose the protocol “mac-p” to search thermal camera on  Device Management Interface; Remark: Disable PC’s Automatic acquisition of IP addresses, set PC’s Lan local network IP address as the same segment as thermal camera’s;...
  • Page 7: Figure 4 Search And Add The Visible Light Camera To Be Managed

    Remark: make sure PC’s Lan local network IP address as the same network segment as in  the thermal imaging camera’s; The Default IP for thermal camera is 192.168.1.64;  Figure 4 Search and add the visible light camera to be managed 2) Double click the shown-up device on the list, and input user name and password;...
  • Page 8: Referential Point Setting

    Figure 5 Online preview of the dual spectrum camera 2) Choose the display window first by single click the window, then choose the camera which will be displayed on this window. Referential point setting Click enable reference point, and a reference point will appear in the screen (yes, my name is a reference point).
  • Page 9: Smart (Face Detection) Temperature Measurement Setting

    example, Sp1 is the upper left corner of the Blackbody, Sp2 is a point on the bracket (refer to the picture below), and click position correction (Sp1, Sp2). 3) Test: Please let somebody walks around in front of the image to see whether the position of the picture alarm frame is consistent.
  • Page 10: Alarm Setting

    Figure 8 AI Detect Alarm setting Figure 9 Set the multi-levels over temperature alarming threshold 1. The information bar on the right side of the system interface sets the third-level alarm temperature as 33℃. When an object is higher than the temperature, a green box will be...
  • Page 11: Figure 10 Alarm Event (Image Capture And Sound Alarm)

    drawn for alarm (the temperature can be set according to the actual situation). 2. The information bar on the right side of the system interface sets the second-level alarm temperature as 36℃. When an object is higher than the temperature, a yellow box will be drawn for alarm (the temperature can be set according to the actual situation).
  • Page 12: Device Upgrade

    Device upgrade The "Remote upgrade" function is to upgrade the firmware version of the camera modules and boards. Enter “Remote configuration” ---- click on “Remote upgrade”. Please refer to the following figures steps. Figure 11 To enter the remote upgrade interface...
  • Page 13: Figure 12 Click Maintenance And Then "Remote Upgrade

    Figure 12 Click maintenance and then “Remote upgrade” 5.6.1 DSP Firmware upgrade Choose the corresponding file, click “open” to upgrade.
  • Page 14: Figure 13 Upgrade The Dsp Firmware

    Figure 13 Upgrade the DSP firmware After the progress bar shows 100%, it returns to zero(red box 1). When the red box 2 appears on the screen, restart the device (red box 3).
  • Page 15: Figure 14 Upgrade The Dsp Firmware

    Figure 14 Upgrade the DSP firmware 5.6.2 Hisilicon firmware upgrade Please follow the steps instruction below Upgrade the “.pkg” file Do not reboot when the progress bar shows 100%. Reboot it according to the instructions of the image (When shows “Upgrade completed, please restart”, then reboot).
  • Page 16: Figure 15 Upgrade The Hisilicon Firmware (To Begin)

    Figure 15 Upgrade the Hisilicon firmware (To begin) After each program file is successfully upgraded, then reboot the device. Figure 16 Upgrade the Hisilicon firmware (successfully completed) After upgrading, delete the original device in “Device Management”; Refresh and add the device.
  • Page 17: Osd Setting

    Figure 17 Add the device after upgrading firmware 5.7 OSD setting Support the display of some information such as time, channel, and temperature marker overlay. Figure 18 OSD settings...
  • Page 18: Image Setting

    5.8 Image setting Support setting of some parameters for images and the image mirror to change the image display. Figure 19 Image settings 6 Marking the measuring area Set up a human body temperature measurement area upon situation on site. Landmark lines or temporary fences are normally used to set up human body temperature measurement areas.