Eeprom Factory Default Data Setup Procedure - Panasonic WH-UD07HE5 Service Manual

Air-to-water heatpump
Hide thumbs Also See for WH-UD07HE5:
Table of Contents

Advertisement

14.8 EEPROM Factory Default Data Setup Procedure

- EEPROM default data setup is only possible during initialization process.
- Press
(
,
,
,
)
simultaneously for 5secs continuously, initialization process
will stop & EEPROM default data setup process will start.
During EEPROM default data setup process, display should be as shown below.
0.2s
Later
0.2s
Later
0.2s
Later
- Once EEPROM default data setup process is complete, initialization process will re-start from beginning.
Real time and date will blink