5
Command description
Command
GAJ
Obtaining various adjustment values
GPD
Obtaining power-down-point log
GPW
Obtaining panel white-balance adjustment values
GS1
Obtaining information on the unit, such as the software version
GS2
Obtaining information on the status of the unit
GSD
Obtaining information on shutdown
GAJ: Obtaining data on ABL setting values, electronic-control adjustment values, and drive-system adjustment values
Order
1
ABL table currently used
2
Upper limit of power
3
Vsus adjustment value
4
Vofs adjustment value
5
X-SUS-U1 adjustment value (XU1)
6
X-SUS-U2 adjustment value (XU2)
7
X-SUS-D2 adjustment value (XD2)
8
X-SUS-D1 adjustment value (XD1)
9
Y-SUS-U1 adjustment value (YU1)
10
Y-SUS-U2 adjustment value (YU2)
11
Y-SUS-D1-2 adjustment value (YD2)
12
Y-SUS-D1-1 adjustment value (YD1)
13
Y-SUS-D2-2 adjustment value (YD4)
14
Y-SUS-D2-1 adjustment value (YD3)
Note: Ignore the 2-byte checksum at the end.
GPD: Obtaining power-down-point log on the panel
Order
1
Latest "1st PD" data
2
Latest "2nd PD" data
3
Data of hour meter for the latest PD
4
Data on temperature for the latest PD (TEMP1)
5
Second latest "1st PD" data
6
Second latest "2nd PD" data
7
Data of hour meter for the second latest PD
8
Data on temperature for the second latest PD (TEMP1)
9
Third latest "1st PD" data
10
Third latest "2nd PD" data
11
Data of hour meter for the third latest PD
12
Data on temperature for the third latest PD (TEMP1)
13
Fourth latest "1st PD" data
14
Fourth latest "2nd PD" data
15
Data of hour meter for the fourth latest PD
16
Data on temperature for the fourth latest PD (TEMP1)
17
Fifth latest "1st PD" data
18
Fifth latest "2nd PD" data
19
Data of hour meter for the fifth latest PD
20
Data on temperature for the fifth latest PD (TEMP1)
21
Sixth latest "1st PD" data
22
Sixth latest "2nd PD" data
23
Data of hour meter for the sixth latest PD
24
Data on temperature for the sixth latest PD (TEMP1)
25
Seventh latest "1st PD" data
26
Seventh latest "2nd PD" data
27
Data of hour meter for the seventh latest PD
28
Data on temperature for the seventh latest PD (TEMP1)
29
Eighth latest "1st PD" data
30
Eighth latest "2nd PD" data
31
Data of hour meter for the eighth latest PD
31
Data on temperature for the eighth latest PD (TEMP1)
Notes: • Ignore the 2-byte checksum at the end.
5
6
Function
Data
Data
• For details, see "Description on power-down."
6
7
Size
Remarks
1 byte
0-C or F
1 byte
0-C or F
7 bytes
1st-5th byte: Hour, 6th-7th byte: Minute
3 bytes
000 - 255
1 byte
0-C or F
1 byte
0-C or F
7 bytes
1st-5th byte: Hour, 6th-7th byte: Minute
3 bytes
000 - 255
1 byte
0-C or F
1 byte
0-C or F
7 bytes
1st-5th byte: Hour, 6th-7th byte: Minute
3 bytes
000 - 255
1 byte
0-C or F
1 byte
0-C or F
7 bytes
1st-5th byte: Hour, 6th-7th byte: Minute
3 bytes
000 - 255
1 byte
0-C or F
1 byte
0-C or F
7 bytes
1st-5th byte: Hour, 6th-7th byte: Minute
3 bytes
000 - 255
1 byte
0-C or F
1 byte
0-C or F
7 bytes
1st-5th byte: Hour, 6th-7th byte: Minute
3 bytes
000 - 255
1 byte
0-C or F
1 byte
0-C or F
7 bytes
1st-5th byte: Hour, 6th-7th byte: Minute
3 bytes
000 - 255
1 byte
0-C or F
1 byte
0-C or F
7 bytes
1st-5th byte: Hour, 6th-7th byte: Minute
3 bytes
000 - 255
PDP-504PU
7
8
Size
Remarks
3 bytes
AB1 - AB3
3 bytes
000 - 255
3 bytes
000 - 255
3 bytes
000 - 255
3 bytes
000 - 255
3 bytes
000 - 255
3 bytes
000 - 255
3 bytes
000 - 255
3 bytes
000 - 255
3 bytes
000 - 255
3 bytes
000 - 255
3 bytes
000 - 255
3 bytes
000 - 255
3 bytes
000 - 255
8
A
B
C
D
E
F