2.17

Horizontal position adjustment

Adjustment preparation
(1) The screen face of set should be turned to East
or West.
(2) VIDEO control should be set to Factory Preset
Condition.
(3) DIGITAL CONVERGENCE adjustment should
be finished.
Adjustment procedure
NORMAL 16:9 STANDARD MODE
(1) Receive circle pattern.
(2) Picture Format is 16:9 Standard.
C Adj. mode by pressing the R/C keys
(3) Go to I
2
MENU + MENU + MENU + 8 + SELECT
I²C mode.
(4) Choose
H.
POSITION
THUMBSTICK
(5) Adjust HORIZONTAL POSITION as follows,
using R/C THUMBSTICK
Spec: Balance Left/Right side display position.
H. size marker 1.0~2.0.
Adjustment procedure
1080i 16:9 Standard Mode
(1) Input 1080i (fH=33.75KHz) component circle
pattern signal to component video terminal.
(2) Picture Format is 16:9 Standard.
(3) Go to I
2
C Adj. mode.
(4) Choose
H.
POSITION
THUMBSTICK
(5) Adjust HORIZONTAL POSITION as follows,
using R/C THUMBSTICK
Spec: Balance Left/Right side display position.
BACK TO ADJUSTMENTS
to enter the
item
using
R/C
, .
, .
item
using
R/C
, .
, .

2.18 Scanning area check

Checking condition
(1) Digital convergence adjustment should have been
completed.
(2) Receive the circle pattern signal.
(3) Brightness/Contrast - standard condition
Contrast:max
Other controls:center position
(4) Check that the scanning area matches with the
following drawing.
Receive 1080i circle pattern No. 59 of LT1611*, LT1608* of
LEADER signal generator.
Receive 1080i circle pattern of LT-449 (Leader)