5) Operation of device
1. LOCAL / REMOTE common items
(1)"EMERGENCY" switch
Press this switch to turn the device into emergency stop, jump to main
unit emergency stop screen, and stop UV radiation.
Follow the procedure displayed on touch screen to resume from
emergency stop state.
(2)"Temperature feedback ON / OFF" key
By pressing this key and achieving "temperature feedback ON," the
function to detect LED head temperature and stabilize UV intensity will
be activated.
However, this function will be deactivated even under "temperature
feedback ON" if the dimming rate is set to 100% in program setting
screen as in P.37.
Also, this function will be deactivated if the dimming rates are not
identical for all the blocks of LED head.
Temperature feedback ON state
(3)"LED head" status display area
Displays lit LED blocks while LED radiation is on, as illustrated in the
bottom left corner of screen.
(4)"Data menu" key
Press this key to jump to data menu screen.
See P.36 for details.
Front panel
Main screen
Temperature feedback invalid state
- 34 -
Main unit emergency stop screen
UV radiation underway screen