• When using this unit close to the vehicle's battery and engine, stand the unit on a flat, stable surface, and be sure to keep all clamps,
cords, clothing and body parts away from moving vehicle parts.
• Never allow red and black clamps to touch each other or another common metal conductor — this could cause damage to the unit and/
or create a sparking/explosion hazard.
– a) For negative-grounded systems, connect the positive (red) clamp to the positive ungrounded battery post and the negative (black)
clamp to the vehicle chassis or engine block away from the battery. Do not connect the clamp to the carburetor, fuel lines or sheet-
metal body parts. Connect to a heavy gage metal part of the frame or engine block.
– b) For positive-grounded systems, connect the negative (black) clamp to the negative ungrounded battery post and the positive (red)
clamp to the vehicle chassis or engine block away from the battery. Do not connect the clamp to the carburetor, fuel lines or sheet-
metal body parts. Connect to a heavy gage metal part of the frame or engine block.
• If the connections to the battery's positive and negative terminals are incorrect, the backlit LCD screen will blink and display the battery
status, the voltage indicator, and the Alarm Icon. The "+" and "–" signs above the Battery Icon will flash and the unit will sound a
continuous alarm until the clamps are disconnected. Disconnect clamps and reconnect to battery with correct polarity.
• Always disconnect the negative (black) jumper cable first, followed by the positive (red) jumper cable, except for positive grounded
systems.
• Do not expose battery to fire or intense heat since it may explode. Before disposing of the battery, protect exposed terminals with
heavy-duty electrical tape to prevent shorting (shorting can result in injury or fire).
• Place this unit as far away from the battery as cables permit.
• Never allow battery acid to come in contact with this unit.
• Do not operate this unit in a closed area or restrict ventilation in any way.
• This system is designed to be used only on vehicles with a 12 volt DC battery system. Do not connect to a 6 volt or 24 volt battery system.
• This system is not designed to be used as a replacement for a vehicular battery. Do not attempt to operate a vehicle that does not have
a battery installed.
• Excessive engine cranking can damage a vehicle's starter motor. If the engine fails to start after the recommended number of attempts,
discontinue jump-start procedures and look for other problems that may need to be corrected.
• Do not use this jump starter on a watercraft. It is not qualified for marine applications.
• Although this unit contains a non-spillable battery, it is recommended that unit be kept upright during storage, use and recharging.
To avoid possible damage that may shorten the unit's working life, protect it from direct sunlight, direct heat and/or moisture.
SPECIFIC SAFETY INSTRUCTIONS FOR INVERTERS
WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK:
• Do not connect to AC distribution wiring.
• Do not make any electrical connections or disconnections in areas designated as IGNITION PROTECTED. This inverter is NOT approved for
ignition protected areas.
• Never immerse the unit in water or any other liquid, or use when wet.
WARNING: TO REDUCE THE RISK OF FIRE:
• Do not operate near flammable materials, fumes or gases.
• Do not expose to extreme heat or flames.
CAUTION: TO REDUCE THE RISK OF INJURY OR PROPERTY DAMAGE:
• Disconnect appliance plug from inverter outlet before attempting any repairs to the appliance.
• When an appliance plugged into this unit is used outdoors, use only extension cords intended for use outdoors and so marked.
• Do not attempt to connect the inverter while operating your vehicle. Not paying attention to the road may result in a serious accident.
• Always use the inverter where there is adequate ventilation.
• Always turn the inverter off when not in use.
• Keep in mind that this inverter will not operate high wattage appliances or equipment that produce heat, such as hair dryers, microwave
ovens and toasters.
• Do not use this inverter with medical devices. It is not tested for medical applications.
• Operate inverter only as described in this Instruction Manual.
SPECIFIC SAFETY INSTRUCTIONS FOR COMPRESSORS
CAUTION: TO REDUCE THE RISK OF INJURY OR PROPERTY DAMAGE: Never leave the compressor unattended while in use.
WARNING: BURST HAZARD: BURSTING ARTICLES CAN CAUSE SERIOUS INJURY.
• Carefully follow instructions on articles to be inflated.
• Never exceed the recommended pressure listed in instructions on articles to be inflated. If no pressure is given, contact article
manufacturer before inflating.
• Monitor the pressure at all times on the pressure gage.
CAUTION: TO REDUCE THE RISK OF PROPERTY DAMAGE:
Do not operate compressor continuously for longer than approximately 10 minutes, depending on ambient temperatures, as it may
overheat.
PPRH5_ManualENSP_091415.indd 6-7
6
6
FIRST AID
• Skin: If battery acid comes in contact with skin, rinse immediately with water, then wash thoroughly with soap and water. If redness,
pain, or irritation occurs, seek immediate medical attention.
• Eyes: If battery acid comes in contact with eyes, flush eyes immediately, for a minimum of 15 minutes and seek immediate medical
attention.
SAVE THESE INSTRUCTIONS
INTRODUCTION
Congratulations on purchasing your new
Stanley
®
Powerit™ Professional Power Station.
instructions carefully before using this unit.
CHARGING/RECHARGING
Lead-acid batteries require routine maintenance to ensure a full charge and long battery life. All batteries lose energy from self-discharge
over time and more rapidly at higher temperatures. Therefore, batteries need periodic charging to replace energy lost through self-
discharge. When the unit is not in frequent use, manufacturer recommends the battery be recharged at least every 30 days.
IMPORTANT: If you know the unit is discharged, but the battery status LEDs illuminate as if the unit is fully charged when connected to
a charging power source, this may be due to the internal battery having high impedance. The manufacturer suggests leaving the unit
charging for a period of 40 hours using the built-in AC charger before use.
WARNING: Never attempt to use the AC and DC charging methods at the same time.
Notes:
This unit is delivered in a partially charged state – you must fully charge it before using it for the first time. Initial AC charge should be for 40 hours.
Recharging battery after each use will prolong battery life; frequent heavy discharges between recharges and/or overcharging will reduce battery life.
Make sure all other unit functions are turned off during recharging, as this can slow the recharging process.
CAUTION: RISK OF PROPERTY DAMAGE: Failure to keep the battery charged will cause permanent damage and result in poor jump
starting performance.
Charging/Recharging Using the 120 Volt AC Charger and a Standard Household Extension Cord (not
included)
1. Lift the cover built-in 120 volt AC charger located on the lower left front of the unit (refer to the Features section to locate). Connect
an extension cord to the unit. Plug the other end of the cord into a standard 120-volt AC wall outlet.
2. Charge until two red LED battery status indicators light and one green LED battery status indicator lights or flashes.
3. Disconnect the extension cord.
Notes:
The unit cannot be overcharged using the AC method.
The unit will not charge if the inverter power switch is turned on.
12 Volt DC Charging Method (may be sold separately)
WARNING: NEVER connect this unit to a positive grounded vehicle using the 12 Volt DC Adapter.
The DC recharging method will NOT recharge the unit as effectively as recharging from 120 volt AC. The 12 volt DC recharging procedure
is recommended only when it is necessary, since frequent use of the 12 volt DC recharging procedure may shorten the battery system's life.
Charging the unit from an external 12 volt DC power source requires the use of the 12 Volt DC adapter. This adapter has a male DC
connector at each end.
1. Insert the gold-tipped 12 Volt DC Charging Adapter plug into the vehicle's 12 volt DC accessory outlet.
2. Insert the silver-tipped end plug into the 12 volt DC accessory outlet on the front panel of the unit.
3. Charge the unit until the green FULL indicator lights when the Battery Power Level Button is pressed (with the adapter unplugged
from the unit). DO NOT CHARGE MORE THAN 6 HOURS MAXIMUM USING THIS METHOD.
4. When charging is complete, remove the charging cord and store in a safe place.
Notes:
Some vehicles require that the ignition be switched to the accessory outlet position in order to power the accessory outlet.
Do not leave the unit unattended when charging using the this method.
JUMP-STARTER
This Jump-Starter is equipped with an On/Off Power Switch. Once the connections are properly made, turn the switch on to jump-start the
vehicle.
1. Turn off vehicle ignition and all accessories (radio, A/C, lights, connected cell phone chargers, etc.). Place vehicle in "park" and set the
emergency brake.
2. Make sure the Jump-Starter Power Switch is turned to off.
3. Remove jumper clamps from clamp tabs. Connect the red clamp first, then the black clamp.
4. Procedure for jump-starting a NEGATIVE GROUNDED SYSTEM (negative battery terminal is connected to chassis)
(MOST COMMON)
4a. Connect positive (+) red clamp to vehicle battery' s positive terminal.
4b. Connect negative (–) black clamp to chassis or a solid, non-moving, metal vehicle component or body part. Never clamp directly to
negative battery terminal or moving part. Refer to the automobile owner' s manual.
5. Procedure for jump-starting POSITIVE GROUND SYSTEMS