ZS-30A / ZS-40A
Input: DC12V Solar panel (Max. 25V)
Output: DC 12V 30A (ZS-30A)
DC 12V 40A (ZS-40A)
User's Manual
1

Advertisement

loading

Summary of Contents for Zamp Solar ZS-30A

  • Page 1 Solar Controller / Battery Charger ZS-30A / ZS-40A Input: DC12V Solar panel (Max. 25V) Output: DC 12V 30A (ZS-30A) DC 12V 40A (ZS-40A) User’s Manual...
  • Page 2 ●Surface Mount or Flush Panel Mount options. ●Conformal-coating circuit boards and plated terminals apply to hostile environments. For use with 12Volt Solar Panel Only Suitable for Solar panels up to 510 Watts / ZS-30A; 680Watt / ZS-40A...
  • Page 3 WARNING – IMPORTANT PLEASE READ ● This charger is designed for indoor use only and should never be exposed to rain. ● Do not disassemble the controller. Take to a qualified person if the unit requires repairing. ● Lead acid, LiFePO4, LTO batteries can be dangerous. Ensure no sparks or flames are present when working near batteries.
  • Page 4: Wiring Connections

    To protect the Battery and the Solar Panel, we strongly recommend that you place a 40A inline fuse for ZS-30A (60A fuse for ZS-40A) on the positive wire on both the “Solar” and “Battery” Circuits. (As close to the Battery /Panel as possible) The Solar Controller has 4 terminals which are clearly marked ‘Solar’...
  • Page 5: Charging Stages

    Press BATTERY TYPE button and hold for 3 seconds to go into your battery type selection mode, the battery type you select will be shown on the LCD meter, the default setting is AGM Battery; the controller will automatically memorize your battery type setting.
  • Page 6 Soft Charge- When batteries suffer an over-discharge, the controller will softly ramp the battery voltage up to 10V. Bulk Charge-Maximum current charging until batteries rise to Absorption level Absorption Charge-Constant voltage charging and battery is over 85%. Equalization Charge*-Only for WET battery or Calcium battery type, when the battery is deeply drained below 10V, it will automatically run this stage to bring the internal cells as an equal state and fully complement the loss of capacity.
  • Page 7 Solar panel abnormal LCD display LED indication LCD backlight mode Solar panel weak Flash Solar panel reverse Flash connection Flash Solar panel over voltage Flash (> 26.5V) Flash Battery abnormal mode LCD display LED indication LCD backlight Battery disconnected or Flash less than 3.0V Flash...
  • Page 8: Specifications

    0.25 Max. Charging characteristics Minimum battery start charging voltage Soft start charging voltage 3-10 +/-0.2 VDC Soft start charging current ZS-30A / ZS-40A Up to 15 / 20 Bulk charge voltage 10-14.0 +/-0.2 VDC Absorption charging voltage at 25 ℃...