SK-NIC-KIT Remote Mounting
Kit
The SK-NIC-KIT is a remote mounting kit that
lets you install up to two SK-NIC Network
Interface cards in a single cabinet. SK-NIC-KIT
includes the SK-NIC, a small cabinet with door,
cable, and mounting hardware
Note: Installation and wiring of this device must be done in
accordance with NFPA 72 and local ordinances.
Specifications
Dimensions: 10-3/8"W x 10-3/16"H x 3"D
(26.4 cm W x 25.9 cm H x 7.6 cm D)
Compatibility
The SK-NIC-KIT is compatible with the SK-NIC
Network Interface Card. It also has room for one
6815 SLC expander inside the cabinet.
Mounting
It is important to protect the SK-NIC-KIT and its
contents from water. To prevent water damage,
follow the mounting requirements listed below:
Do not mount directly on exterior walls,
especially masonry walls (condensation)
Do not mount directly on exterior walls below
grade (condensation)
Protect from plumbing leaks
Protect from splash caused by sprinkler
inspection ports
Do not mount in areas with humidity
generating equipment (such as dryers, pro-
duction machinery)
Mount in an area that always remains within
the following temperature and humidity
range: 0° to 49° C (32° to 120° F) and 10-
93% at 86°F(30°C) non-condensing.
Mount in an indoor, dry location.
SK-NIC-KIT Remote Mounting Kit
Product Installation Document
PN LS10171-001SK-E:A 07/01/2017 ECN 16-0218
Warning!:
The electronic components on the SK-NIC and the FACP
are sensitive to electrostatic discharge. Wear a grounding
strap when handling any of the boards.
To mount the SK-NIC-KIT cabinet:
1. Remove the SK-NIC-KIT from its packing
container.
2. Unlock the SK-NIC-KIT cabinet and lift up on
the cabinet door to remove it.
3. Unscrewing the two mounting plate screws
as shown in Figure 1 to remove the
mounting plate.
Figure 1. Remove the Two Mounting Plate Screws to
Expose the Cabinet Mounting Holes
4. Mount the cabinet using the appropriate

Advertisement

loading

Summary of Contents for Honeywell SK-NIC-KIT

  • Page 1 Interface cards in a single cabinet. SK-NIC-KIT container. includes the SK-NIC, a small cabinet with door, 2. Unlock the SK-NIC-KIT cabinet and lift up on cable, and mounting hardware the cabinet door to remove it. Note: Installation and wiring of this device must be done in 3.
  • Page 2 6. Insert the eight standoffs included with the cabinet as shown in Figure 3. Figure 3 : Standoff Installation Farenhyt is a trademark, Silent Knight and Honeywell are registered trademarks of Honeywell International, Inc. ™ ® ® SK-NIC-KIT Installation Document — P/N LS10171-001SK-E:A 07/01/2017...