Fujitsu ASYG12LLCE Service Manual

Fujitsu ASYG12LLCE Service Manual

Split type room air conditioner wall mounted type
Hide thumbs Also See for ASYG12LLCE:

Advertisement

SPLIT TYPE
ROOM AIR CONDITIONER
WALL MOUNTED TYPE
Indoor unit
ASYG12LLCE
CO NT ENT S
SPECIFICATIONS. . . . . . . . . . . . . . . . . . .
DIMENSIONS . . . . . . . . . . . . . . . . . . . . . .
CIRCUIT DIAGRAM . . . . . . . . . . . . . . . . .
PCB CIRCUIT DIAGRAM . . . . . . . . . . . . .
ERROR DETECTION . . . . . . . . . . . . . . . .
PARTS (INDOOR UNIT) . . . . . . . . . . . . . .
PARTS (OUTDOOR UNIT) . . . . . . . . . . .
ACCESSORIES . . . . . . . . . . . . . . . . . . .
Outdoor unit
AOYG12LLCE
1
2
4
5
6
8
9
13
16

Advertisement

Table of Contents
loading

Summary of Contents for Fujitsu ASYG12LLCE

  • Page 1: Table Of Contents

    ROOM AIR CONDITIONER WALL MOUNTED TYPE Indoor unit Outdoor unit ASYG12LLCE AOYG12LLCE CO NT ENT S SPECIFICATIONS....DIMENSIONS ..... .
  • Page 2: Specifications

    S P E C IF I C ATIO N S ELECTRICAL DATA FAN MOTOR NOISE LEVEL INDOOR UNIT ASYG12LLCE High 43 dB INDOOR UNIT’S Discrimination MFD-12BYW Medium 38 dB OUTDOOR UNIT AOYG12LLCE OUTDOOR UNIT’S Discrimination MFE-22AVAL INDOOR UNIT Cooling 33 dB...
  • Page 3: Dimensions

    DI ME NS IO NS INDOOR UNIT 820 mm 206 mm Drain hose 600 mm Diameter Outside Inside : 13.8 mm 2016.11.21...
  • Page 4 OUTDOOR UNIT 663 mm 293 mm 454 mm 2016.11.21...
  • Page 5: Refrigerant System Diagram

    REF R IGER A N T SYS T EM D IA GR A M Heat exchanger (indoor unit) Refrigerant direction Cooling 2-way valve Heating 3-way valve Compressor Refrigerant pipe diameter Liquid : 1/4" (6.35 mm) Muffler Strainer Gas : 3/8" (9.52 mm) 4-way valve Expansion valve Heat exchanger...
  • Page 6: Circuit Diagram

    C IR C U I T D I AG R AM OUTDOOR UNIT INDOOR UNIT Reactor Main PCB CN201 Main PCB U(R) Brown Louver White Gray White ( Up / Down ) White Orange Compressor V(S) White Yellow Indicator W(C) White Pink Black...
  • Page 7: Pcb Circuit Diagram

    EARTH PCB CIRCU I T DI AG RA M TERMINAL EMI FILTER *12Type only ZC7KT 14x8x14 CONTROL UNIT ASYG12LLCE : EZ-0131LHSE OUTDOOR UNIT Thermistor Characteristics. WHITE BLACK Temperature Thermistor 176.0 k 62.9 k 39.6 k Thermistor ( Pipe temp. ) 1.1 V...
  • Page 8 INVERTER ASSEMBLY AOYG12LLCE : EZ-0131RHUE Compressor Winding resistance 1.30 EMI FILTER ESD-R-16C e.t.c. REACTOR 2 TURNS TERMINAL EMI FILTER 13mH 8A UL3271 ZCAT2132-1130 AWG18 TO I NDOOR UNIT 1 TURN UL1015 UL3271 AWG22 AWG18 W101 BLACK WHITE UL3271 UL1015 AWG18 AWG22 BLACK W102...
  • Page 9: Error Detection

    E RR OR D ET EC TION OPERATION TIMER ECONOMY 1 flash 1 flash Serial communication error Indoor unit PCB model information error Manual auto switch error Room temp. sensor error Indoor unit Heat Ex. Middle temp.sensor error Indoor unit fan motor error Indoor unit error Outdoor unit main PCB model information error or communication error...
  • Page 10: Parts (Indoor Unit)

    P A R T S Ref. Description Part number INDOOR UNIT Remote Control 9332598001 ASYG12LLCE Air Filter 9332549010 Intake Grille (no brand) 9332629163 Receiver Window 9332546019 Front Panel 9332545012 Wire Cover 9332544008 Louver 9333342009 Panel Cover 9332559002 Wire shield Bracket panel...
  • Page 11 Ref. Description Part number Box shield assy Control Box 9332542004 Main PCB 9709170199 Terminal 9900720001 Display Assy 9709173015 Room Thermistor Holder 9316895003 Thermistor Assy 9900938017 Cover shield INDOOR UNIT ASYG12LLCE Control box Earth terminal 2016.11.11...
  • Page 12 INDOOR UNIT ASYG12LLCE Evaporator Ref. Description Part number Evaporator Total Assy 9316893207 Fan Motor 9603180003 Crossflow Fan Assy 9316830004 Bearing C Assy 9306628017 Casing Assy 9332613018 2016.11.22...
  • Page 13 INDOOR UNIT ASYG12LLCE Casing assy Ref. Description Part number Casing 9332534009 Motor Cover 9316601000 Motor Cover 9316568006 Casing Cover F 9332558005 Casing Cover B 9332557008 R and L Louver 9332535006 Step Motor 9900725006 Fan Guard 9332551006 Drain Cap 9316177017 Drain Hose Assy 9316904002 2016.11.11...
  • Page 14: Parts (Outdoor Unit)

    PART S OUTDOOR UNIT AOYG12LLCE Ref. Description Part number Protective Net 9332855005 Thermistor Holder 9332505009 Top Panel Assy 9332977004 Front Panel Assy 9332965001 Cabinet Left Assy 9332962000 Emblem 9319396019 Cabinet Right Assy 9332963007 Switch Cover A Assy 9332964011 Switch Cover B 9332843002 Drain Assy 9332574005...
  • Page 15 OUTDOOR UNIT Ref. Description Part number AOYG12LLCE Propeller Fan 9309909014 Fan Motor 9603074012 Reactor Assy 9900787028 PCB Holder 9332506013 Main PCB with Terminal 9709434239 Heat Sink B 9332522006 Thermistor Assy 9900901011 Thermistor 9900880019 2016.11.22...
  • Page 16 OUTDOOR UNIT AOYG12LLCE Ref. Description Part number Condenser Total Assy 9333013008 Compressor Assy 9333141008 Solenoid 9970079030 4-way Valve Assy 9333135007 Expansion Valve Coil 9970137013 Pulse Motor Valve Sub Assy 9333023007 2016.11.14...
  • Page 17: Accessories

    AC C E S S OR I ES Name and Shape Part number Name and Shape Part number Wall hook bracket Battery (penlight) 0600185541 9332556001 Cloth tape 9310519004 Remote control Tapping screw (big) 4 x 25) 0700076046 9332598001 Drain pipe assy 9332574005 2013.09.30...
  • Page 18 1611G4557...

This manual is also suitable for:

Aoyg12llce

Table of Contents