10.2.10 TELEPHONE-IN to LINE-OUT Circuit

Nominal level, maximum level and bandwidth
G1
Sine-Wave
Generator
-
+
Amplitude
Nominal level
-14dBV (200mV
Maximum level
+11dBV (3.55V
Bandwidth
-14dBV (200mV
Bandwidth
-14dBV (200mV
LBB 3310/00, 3330/00 and 3331/00
4822 861 11006
90 ... 264V AC
~
~
Power Supply
AC
24V DC
PCB CPSU
X10
Loudspeaker
(GND)
M110 M111
M121
X110
6
9
4
8
Line-IN
Rec-IN
L
Figure 12
settings for G1
Frequency
)
1kHz
rms
)
1 kHz
rms
)
125 Hz
rms
)
12.5 kHz
rms
page: 24
X205 M119
25Ω
M2
(GND)
(GND)
M122 M124
M150 M151
2
7
2
5
X150
Rec-IN
Telephone-IN
R
measurement results for A1
Amplification
-14dBV +/- 1dB (85dB SPL)
+11dBV +/- 1dB (110dB SPL)
-0.5dB +/- 2dB related to nom. level at 1kHz
-0.5dB +/- 1dB related to nom. level at 1kHz.
SERVICE MANUAL
X110
A1
5
Line-OUT
+
V
GND
-
003_012.cdr