Turbidity Sensor - GE GDF510PGDBB Manual

2012 plastic tub dishwasher
Hide thumbs Also See for GDF510PGDBB:
Table of Contents

Advertisement

Located on the side of the sump.
Operates same as today
Calibration is automatic every 100 cycles
After the last rinse but before dry, the control will add 3 extra
rinse cycles. The first will fill, circulate 2 minutes and drain. The second
will be a fill and drain. The third will be a fill, circulate and calibrate,
then a drain. The cycle will now advance to drain and complete the
cycle.
Replacement controls will enter a calibration as mentioned
above at the end of the 1
interrupted and calibration does not occur, calibration will retry on the
next cycle, until it is completed. Calibration will not occur on demand
Note: If the turbidity sensor circuit fails to open or is shorted, the unit
will operate for the maximum amount of time, using the maximum
number of wash and rinse fills for the selected cycle.

Turbidity Sensor

st
cycle the control finishes. If the first cycle is
109 /
Copyright General Electric 2011
9/23/2012