8.4 The installation of more than one appliance
Added parts:connection bar(s), heat re-
sistant silicon, rubber shape, sealing
strap.
580 mm
+
-
=
360 mm
20 mm
920 mm
Only use special a heat - resistant
silicon.
The worktop cut out
Distance from the wall : minimum 50 mm
Depth : 490 mm
Width : sum widths of all the appliances
to be built-in and subtract 20 mm (see
also "Overview of all appliance widths" )
The installation of more than one appli-
ance
1.
Put down the dimension of the work-
top cut out and saw it out.
2.
Put the appliances one at time on
some soft surface, a blanket for ex-
ample, with the bottom side up.
3.
Put the seal stripe around the lower
edge of the appliance along the
outer edge of the glass ceramic.
4.
Loosely screw the fixing plates into
the appropriate holes in the protec-
tive casing.
5.
Put the first appliance in the work-
top cut out. Put the connection bar
in the worktop cut out and push up
half of the width against the appli-
ance.
6.
Loosely turn in fixing plates from
below on the worktop and on the
connection bar.
7.
Put the subsequent appliance in the
worktop cut out . Make sure that the
front ends of the appliances are on
the same level.
8.
Tighten the fixing plate / retaining
grip screws.