Changing Tool Configuration ("Extended"/"Standard"); Preparing Connection - RIDGID RP 342-XL Manual

Press tool
Hide thumbs Also See for RP 342-XL:
Table of Contents

Advertisement

Available languages

Available languages

RP 342-XL Press Tool
Figure 6A – Fully Open Attachment Mounting Pin
< 0.39"
(10 mm)
Figure 6B – Fully Closed Attachment Mounting Pin
Changing Tool Configuration
("Extended"/"Standard")
The RIDGID RP 342-XL Press Tool can be configured for
use with RIDGID Standard or Extended Series attach-
ments (See Specifications for more information). To con-
vert between configurations:
1. Remove any attachment from tool
2. With dry hands, insert a fully charged battery into
tool. Depress ON/OFF button to turn tool ON.
3. From "Standard" to "Extended" Configurations– With
hands clear of the rollers, depress the run switch to
move the rollers forward approximately
Rotate the sleeve to align the "Extended" icon arrow
with the housing arrow (Figure 7).
4. From "Extended" to "Standard" Configurations – With
hands clear of the rollers, depress the run switch to
move the rollers forward till the roller housing is past
the line on sleeve (see Figure 7B). Rotate the sleeve
to align the "Stan dard" icon arrow with the housing
arrow (Figure 7).
8
2
1
1
/
" (3 mm).
8
Figure 7A – "Standard" Configuration
Roller Housing
Line on Sleeve
Figure 7B – "Extended" Configuration
In the "Extended" configuration, the slots of the sleeve will
align with the openings in the housing to allow Extended
Series attachments to mount to the tool. In the "Standard"
configuration, the sleeve will cover part of the housing
openings and prevent the rollers from retracting further
than necessary. This will reduce the tool cycle time in the
"Standard" configuration. Do not use Standard attach-
ments with tool in "Extended" configuration.

Preparing Connection

These instructions are generalized practices for
NOTI E
several types of press tool attachments. Always follow
the specific instructions for the press tool attachment
being used and the fitting manufacturers' specific instal-
lation instructions to reduce the risk of improper press
connections and extensive property damage.
1. Prepare the connection according to the fitting man-
ufacturer's instructions.
2. With dry hands, insert a fully charged battery into
tool. Depress ON/OFF button one time to turn tool ON.
The green light will turn on. See Figure 5 – Tool
Status Lights for any other light. Tool will automatically
turn OFF if left unused for ten (10) minutes.
Pressing A Fitting With Typical Scissor
Jaws
1. Squeeze jaw arms to open jaws.
Arrows Align
Arrows Align
999-999-207.10_REV. A

Advertisement

Table of Contents
loading

Table of Contents