Preface Introduction Installing the Device SIMATIC NET Device Management Rugged Ethernet Switches RUGGEDCOM M969 Communication Ports Technical Specifications Installation Manual Accessories Certification 01/2021 C79000-G8976-1039-03...
Page 3
Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
Warranty Siemens warrants this product for a period of five (5) years from the date of purchase, conditional upon the return to factory for maintenance during the warranty term. This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void.
Siemens Sales representative. Customer Support Customer support is available 24 hours, 7 days a week for all Siemens customers. For technical support or general information, contact Siemens Customer Support through any of the following methods: Online Visit http://www.siemens.com/automation/support-request...
Introduction The RUGGEDCOM M969 is a MIL-STD hardened, fully managed Ethernet switch providing dual fiber optical Fast Ethernet or Gigabit Ethernet ports and eight Fast Ethernet copper ports in a MIL-STD 901D rated package (for protection against vibration and shock impacts) and is IP65/IP67 rated for protection against strong jets of water (IP65) or temporary immersion in water (IP67).
Introduction 1.2 Description • Failsafe output relay for critical failure or error alarming Universal Power Supply Options • Fully integrated power supply • Universal high-voltage range: 88-300 VDC or 85-264 VAC. • Popular low-voltage DC ranges: 12, 24, 48 VDC • Dual redundant, parallel load-sharing power supplies (option) •...
Page 12
Introduction 1.2 Description Copper Ethernet Ports Port Status LED POWER 1 LED POWER 2 LED ALARM LED RS-232 Console Port Failsafe Output Relay M12 Power Supply Port Fiber Optic Ethernet Ports RUGGEDCOM M969 Installation Manual, 01/2021, C79000-G8976-1039-03...
Page 13
Introduction 1.2 Description Surge Ground Connection Chassis Ground Connection Figure 1.1 RUGGEDCOM M969 (M12 Connectors Shown) Copper Ethernet Ports Port Status LED POWER 1 LED RUGGEDCOM M969 Installation Manual, 01/2021, C79000-G8976-1039-03...
Introduction 1.3 Required Tools and Materials POWER 2 LED ALARM LED RS-232 Console Port Failsafe Output Relay M23 Power Supply Port Fiber Optic Ethernet Ports Surge Ground Connection Chassis Ground Connection Figure 1.2 RUGGEDCOM M969 (RJ45 Connectors Shown) Port Status LED Indicate the status of each port. State Description Yellow (Solid)
Siemens recommends using RUGGEDCOM industrial Ethernet shielded cables for all Ethernet ports. Siemens does not recommend the use of copper cabling of any length for critical, real-time substation automation applications. All copper Ethernet ports on RUGGEDCOM products include transient suppression circuitry to protect against damage from electrical transients and conform with IEC 61850-3 and IEEE 1613 Class 1 standards.
Introduction 1.6 Ingress Protection Cable Type Wavelength (nm) Modal Bandwidth Distance (m) (MHz·km) 100Base-FX 1000Base-SX 10GBase-SR 1300 2000 — — OM4 (50/125) 3500 — 1300 2000 — — Laser optimized. Ingress Protection IEC International Standard 60529 (Edition 2.1: 2001-02) is a "classification of degrees of protection provided by enclosures as a system for specifying the enclosures of electrical equipment on the basis of the degree of protection provided by the enclosure."...
This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by Siemens AG could invalidate specifications, test results, and agency approvals, and void the user's authority to operate the equipment.
Installing the Device 2.2 Mounting the Device IMPORTANT If any item is missing or damaged, contact Siemens for assistance. Mounting the Device The RUGGEDCOM M969 is designed to be mounted on a panel by affixing the top and bottom flanges of the device to a panel using screws.
Installing the Device 2.3 Connecting the Failsafe Alarm Relay To mount the device to a panel, do the following: Place the device against the panel and align the flanges with the mounting holes. Flange Figure 2.1 Panel Mounting (Typical) Install the supplied screws to secure the flanges to the panel. Connecting the Failsafe Alarm Relay The Failsafe output relay is provided to signal critical error conditions that may occur on the RUGGEDCOM M969 series switches.
Installing the Device 2.4 Connecting Power The proper relay connections are as follows: Description Normally Closed Common Normally Open Figure 2.2 Failsafe Alarm Relay Wiring Connecting Power The M23 power connector has five terminal pins, which means two power supply sources are allowed to power the RUGGEDCOM M969 with the M23 power connector.
Installing the Device 2.4.2 Power Supply Wiring Terminal # Description Usage bus for DC inputs. This terminal is connected to chassis ground internally. An additional chassis ground screw is also present that connects chassis ground to both power supply surge grounds via a removable jumper. For more information about the jumper, refer to "Disabling Line-to-Ground Transient Protection (Page...
Page 23
Installing the Device 2.4.2 Power Supply Wiring Neutral Safety Line 250 VAC Breaker 110/230 VAC Power Source Safety Earth Figure 2.4 AC Power Supply Wiring Example (M23 Power Connector) Single Low DC Power Supply Wiring M23 Power Connector Ground Bus 300 VDC Breaker DC Power Source Figure 2.5 DC Power Supply Wiring Example (M23 Connector)
Page 24
Installing the Device 2.4.2 Power Supply Wiring 250 VAC Breaker Neutral 110/230 VAC Power Source (PS2) 110/230 VAC Power Source (PS1) Safety Figure 2.6 AC and AC Power Supply Wiring Example M23 Power Connector Ground Bus Line 250 VAC Breaker 110/230 VAC Power Source (PS2) Neutral Safety 300 VDC Breaker...
Installing the Device 2.4.3 Disabling Line-to-Ground Transient Protection Ground Bus 300 VDC Breaker DC Power Source (PS2) DC Power Source (PS1) Figure 2.8 DC and DC Power Supply Wiring Example 2.4.3 Disabling Line-to-Ground Transient Protection All line-to-ground transient energy is shunted to the Surge Ground terminal. In cases where users require the inputs to be isolated from ground, remove the ground braid between Surge and Chassis Ground.
Device Management This section describes how to connect to and manage the device. Connecting to the Device The following describes the various methods for accessing the RUGGEDCOM M969 console and Web interfaces on the device. For more detailed instructions, refer to the RUGGEDCOM M969 User Guide for the RUGGEDCOM M969.
Device Management 3.2 Configuring the Device For more information about available ports, refer to "Communication Ports (Page 19)". Configuring the Device Once the device is installed and connected to the network, it must be configured. All configuration management is done via the RUGGEDCOM RUGGEDCOM M969 interface.
Communication Ports The RUGGEDCOM M969 can be equipped with various types of communication ports to enhance its abilities and performance. To determine which ports are equipped on the device, refer to the factory data file available through RUGGEDCOM M969 . For more information on how to access the factory data file, refer to the RUGGEDCOM M969 User Guide for the RUGGEDCOM M969.
Communication Ports 4.2 Fiber Optic Ethernet Ports cause excessive noise and interference, but more importantly, create a potential shock hazard that can result in serious injury. Pin-Out (RJ45) The following is the pin-out description for the RJ45 connectors: 10/100Base- Description TX Signal Receive Data+ Receive Data-...
Page 31
Communication Ports 4.2 Fiber Optic Ethernet Ports Tx Connector Rx Connector Figure 4.5 LC Port For specifications on the available fiber optic Ethernet ports, refer to "Fiber Optic Ethernet Port Specifications (Page 24)". RUGGEDCOM M969 Installation Manual, 01/2021, C79000-G8976-1039-03...
Technical Specifications This section details the specifications and operating conditions of the device. Power Supply Specifications Power Minimum Maximum Internal Isolation Maximum Supply Type Input Input Fuse Rating Power Consumption 12–24 VDC 10 VDC 36 VDC 3.15A (T) 1.5 kVDC 10 W 24 VDC 18 VDC...
All cabling is duplex type unless otherwise specified. • Maximum segment length is greatly dependent on factors such as fiber quality, and the number of patches and splices. Consult a Siemens sales associate when determining maximum segment distances. • All optical power numbers are listed as dBm averages. To convert from average to peak, add 3 dBm.
Technical Specifications 5.6 Mechanical Specifications Ambient Storage -40 to 85° C (-40 to 185° F) Temperature Ambient Relative 5% to 95% Humidity Maximum Altitude 15240 m (50000 ft) Measured from a 30 cm (12 in) radius surrounding the center of the RUGGEDCOM M969 enclosure. Reduced to -40 to 80 °C (-40 to 76 °F) when equipped with a 100Base-FX, single-mode, 1300 nm, long- reach 90 km port(s).
Accessories This chapter details the various accessories available for the RUGGEDCOM M969. Power (1/unit) M23 Power Mating Connector • Description M23 5pin female connector, 600V, IP68 rated • Order Code 99-60-0007 • Cable Specifications 3/18 AWG, jacket OD range 0.20" - 0.48"...
Accessories 6.4 Ethernet (8/unit) Figure 6.6 M12 FailSafe Port Mating Connector Ethernet (8/unit) M12 D-code Ethernet Port Mating Cable • Description M12 D-code to RJ45; patch cable, 3meters • Order Code 99-43-0040-001 • Cable Specifications M12 D-code male 4 pin, CAT5e, 3m Figure 6.7 M12 D-code Ethernet Port Mating Cable...
Page 42
Accessories 6.4 Ethernet (8/unit) Figure 6.8 M12 D-code Ethernet Port Mating Connector M12 D-Code Ethernet Port Mating Cable • Description M12 male D-code to male D-code; shielded PUR jacket patch cable, 5 meters Order Code • 99-43-0041-001 • Cable Specifications M12 male 4 pin, CAT 5e, 5m Figure 6.9 M12 D-Code Ethernet Port Mating Cable...
Page 43
Accessories 6.4 Ethernet (8/unit) • Description IP67 Metal RJ45 plug on both ends; Category 5e shielded patch cable, • Order Code 99-43-0039-001 Figure 6.11 IP67 Metal RJ45 Ethernet Port Mating Cable IP67 Metal RJ45 Ethernet Port Mating Connector Description • IP67 Metal RJ45 plug, field attachable •...
Accessories 6.5 LC Fiber Optic (2/unit) LC Fiber Optic (2/unit) LC Port Mating Connector Description • Cable Multimode Metal IP67LC to LC, Multimode fiber cable 3meters, IP67 rated • Order Code 99-43-0057-001 Figure 6.14 LC Port Mating Connector • Description Cable Singlemode Metal IP67 LC to LC, Singlemode fiber cable 3 meters, IP67 rated Order Code...
Page 45
Accessories 6.5 LC Fiber Optic (2/unit) Figure 6.16 LC Port Mating Connector • Description Cable Singlemode Metal IP67 LC to Metal IP67 LC, Singlemode fiber cable 3 meters, IP67 rated • Order Code 99-43-0053-001 Figure 6.17 LC Port Mating Connector LC Port Mating Connector •...
Page 46
Accessories 6.5 LC Fiber Optic (2/unit) LC, RJ45 Port Cap • Description RJ45 outlet cap IP67, Metal • Order Code 99-60-0011 Figure 6.20 LC, RJ45 Port Cap RUGGEDCOM M969 Installation Manual, 01/2021, C79000-G8976-1039-03...
UL 62368-1 Information Technology Equipment – Safety Part 1: General Requirements 7.1.2 European Commission (EC) This device is declared by Siemens AG to comply with essential requirements and other relevant provisions of the following EC directives: • EN 60950-1 Information Technology Equipment – Safety – Part 1: General Requirements •...
Methods of Measurement The device is marked with a CE marking and can be used throughout the European community. A copy of the CE Declaration of Conformity is available from Siemens AG. For contact information, refer to "Contacting Siemens (Page vii)".
Support at https://support.industry.siemens.com/cs/ww/en/view/89855782. 7.1.8 RoHS This device is declared by Siemens AG to meet the requirements of the following RoHS (Restriction of Hazardous Substances) directives for the restricted use of certain hazardous substances in electrical and electronic equipment: China RoHS 2 •...
Certification 7.1.9 Other Approvals 7.1.9 Other Approvals This device meets the requirements of the following additional standards: • IEEE 1613 IEEE Standard Environmental and Testing Requirements for Communications Networking Devices in Electric Power Substations • IEC 61000-6-2 Electromagnetic Compatibility (EMC) – Part 6-2: Generic Standards – Immunity for Industrial Environments •...
Certification 7.3 EMC and Environmental Type Tests Test Description High Temperature Method 501.4 Procedure I Storage High Temperature Method 501.4 Procedure II Operational Low Temperature Method 502.4 Procedure I Storage Low Temperature Method 502.4 Procedure II Operational Temperature Shock Method 503.4 Procedure I Storage Acceleration Method 513.5 Procedure II Salt Fog Method 509.4 Procedure I Vibration Method 514.5...
Page 53
Certification 7.3 EMC and Environmental Type Tests Test Description Test Levels Severity Levels IEC 61000-4-29 Voltage Dips DC Power ports 30% for 0.1 s, 60% for — & Interrupts 0.1 s, 100% for 0.05 s AC Power ports 30% for 1 period, —...
Page 54
Certification 7.3 EMC and Environmental Type Tests Description Test Levels HV Impulse Signal ports 5 kV (Failsafe Relay) DC Power ports 5 kV AC Power ports 5 kV Dielectric Strength Signal ports 2 kV DC Power ports 1.5 kV AC Power ports 2 kV Environmental Type Tests Note...
Page 55
Certification 7.3 EMC and Environmental Type Tests RUGGEDCOM M969 Installation Manual, 01/2021, C79000-G8976-1039-03...
Page 56
Further Information Siemens RUGGEDCOM https://www.siemens.com/ruggedcom Industry Online Support (service and support) https://support.industry.siemens.com Industry Mall https://mall.industry.siemens.com Siemens AG Digital Industry Process Automation Postfach 48 48 90026 NÜRNBERG GERMANY...