Transient Recorder (Waveform Capture) - GE Multilin 350 Series Instruction Manual

Feeder protection system
Hide thumbs Also See for Multilin 350 Series:
Table of Contents

Advertisement

SOFTWARE SETUP

3.2.6.2 Transient recorder (Waveform capture)

3–28
Courtesy of NationalSwitchgear.com
A Base curve can be plotted for reference, to customize the operating curve. The Blue
colored curve in the picture (in both curves) is a reference curve. It can be Extremely
Inverse, Definite Time, etc.
The Trip Times in the tables and curves work interactively i.e., changing the table value
will affect the curve shape and vice versa.
The user can save Configured Trip Times.
The user can export Configured Trip Times to a CSV file
The user can load Trip Times from a CSV File
The screen above shows the model followed by 350 for viewing Flexcurves. Select
Initialize to copy the trip times from the selected curve to the FlexCurve.
The EnerVista SR3 Setup software can be used to capture waveforms (or view trace
memory) from the relay at the instance of a pickup, trip, alarm, or other condition.
With EnerVista SR3 Setup software running and communications established, select
the Actual Values > A3 Records > Transient Records menu item to open the
Transient Recorder Viewer window.
Click on Trigger Waveform to trigger a waveform capture. Waveform file numbering
starts with the number zero in the 350, so that the maximum trigger number will
always be one less than the total number of triggers available.
Click on the Save to File button to save the selected waveform to the local PC. A new
window will appear, requesting the file name and path. One file is saved as a
COMTRADE file, with the extension "CFG." The other file is a "DAT" file, required by the
COMTRADE file for proper display of waveforms.
To view a previously saved COMTRADE file, click the Open button and select the
corresponding COMTRADE file.
To view the captured waveforms, click on the Launch Viewer button. A detailed
Waveform Capture window will appear as shown below.