9 Self-Diagnostic Function

9.1.

Self-diagnostic display

This unit is equipped with a self-diagnostic display function which, if a problem occurs, will display an error code corresponding to
the problem.
Use this function when performing maintenance on the unit.
9.2.

How to enter the Self-Diagnostic Function

9.3.
Cassette Mechanism Test (For error code H01, H02, H03, F01, F02)
1. Press "TAPE, DECK 1/2" to select Deck 2.
2. Load a cassette tape with the erasure prevention tab, remove from left side only and close the cassette holder.
3. Press "FAST FORWARD MEMORY" (Tape will be stop after 2 seconds)
4. Load a cassette tape with the erasure prevention tab, remove from right side only and close the cassette holder.
5. Press "REVERSE FM MODE/BP" (Tape will be stop after 2 seconds)
6. Load a pre-recorded tape with both side record tabs intact and close the cassette holder.
7. Press "PLAY/TUNE/TIME ADJ UP" (After TPS function, tape will stop automatically)
8. Press "REC/STOP" (Tape will not move)
9. Press "STOP/TUNE MODE" to indicate Error code.
• If several problem exist, error code will change each time when "
(e.g. H01 → H03 → F01 .....etc.)
10. Press "TAPE, DECK 1/2" to select Deck 1.
11. Repeat step 2 to 9 to test Deck 1. (Tape Deck 1 will not check H02 because of no recording function)
9.4.
CD Mechanism Test (F15, F26, F16, F17, F27, F28, F29, H15, F75)
1. Press "CD".
2. Press "OPEN/CLOSE (1)" and place a CD.
3. Press "OPEN/CLOSE (1)" to close the tray.
4. Press "OPEN/CLOSE (5)" and wait until the tray is open.
5. Press "OPEN/CLOSE (1)" and remove the CD.
6. Press "OPEN/CLOSE (1)" to close the tray.
/TUNE MODE" is pressed.