OY1410 Pulse meter manual
This manual offers a simple 5-step guide for getting started with the sensor, as well as
configuration with Talkpool's Sensepool visualization layer and information for advanced
users.
The OY1400 Industrial communication and control unit is designed with focus on ease-of-use
and reliable operation in LoRaWAN networks. The product is dedicated to be used together
with BMeters' IWM sensor. Normal users will only need to read the 5-step guide at the
beginning of this manual.

Advertisement

loading

Summary of Contents for Talkpool OY1410

  • Page 1 OY1410 Pulse meter manual This manual offers a simple 5-step guide for getting started with the sensor, as well as configuration with Talkpool’s Sensepool visualization layer and information for advanced users. The OY1400 Industrial communication and control unit is designed with focus on ease-of-use and reliable operation in LoRaWAN networks.
  • Page 2 App Key is a securely generated authentication code. The first step you should take is to simply provision the network server, this can be Talkpool’s solution called Sensepool or any other system that you would like to integrate the sensor with, with your App EUI.
  • Page 3: Physical Installation

    Absolute count Pulse length The K-index and Pulse ratio X defines the number of liters per pulse. It is important that the Oy1410 is configured with the same setting. The table below shows the settings for different watermeter models: Watermeter model...
  • Page 4 The cable from IWM-PL3 and IWM-PL4 has four wires. Cut the white wire since it will not be used and might cause short circuits if it is left unconnected inside the OY1410. Feed the cable though the left cable gland.
  • Page 5 Close unit and install in location, you can now view the first data coming in on your application server If you require further support, please contact IoT.support@talkpool.com or your vendor. If you require more advanced information on the OY1410 Pulse meter, please check the next sections.
  • Page 6: Function Description

    “Pulse ratio X”-value in the IWM-PL3 or IWM-PL4, which in turn depends on the type of water meter used. To get the OY1410 to report water volume in liter it is required to set the IWM Pulse Ratio to the same value as Pulse Ratio X in the IWM- PL3 or IWM-PL4.
  • Page 7 Protocol This!describes!the!payload!data!that!is!sent!to!and!from!the!application!server. Uplink command device => network Field Bytes Value Description Note Type 0x01: Data 0x02: Command NACK Index Command Index Data As defined for Command Index (only for Type: Data) Downlink command network => device Field Bytes Value Description Note Type 0x01: Set...
  • Page 8 Commands! Index Description Datatype Encoding Valid range Access Unsolicited Description Note 0x03 FW build hash 6 x Uint8 Query Unique number that identifies the firmware version 0x05 Device reset Action Reset of device 0x06 CPU voltage Uint8 25mV/ 0-3.6V Query Read CPU voltage.
  • Page 9 Command examples! Uplink: 012B0000123401 Current counter value is 1234 = 4660. Status bit 0 is set indicating a reset has been detected. •! Setting the reporting interval to 1440 minutes = 24 hours. Downlink command: 012605A0 •! Reset the Status bits. Downlink command: 012D00 •! Set counter value to 100000 Downlink command: 012C000186A0...