Commissioning/Field Settings Record Sheet - Mitsubishi Electric EHST17D-VM2D Service Manual

Hide thumbs Also See for EHST17D-VM2D:
Table of Contents

Advertisement

Commissioning/Field settings record sheet (continued from the previous page)
Main remote controller screen
Setting
Service
Pump speed
menu
Heat source setting
Heat pump setting
Operation
Heating operation
settings
*12
Freeze stat function *15
Simultaneous operation (DHW/Heating)
Cold weather function
Boiler operation
Smart grid ready
Floor dry up function
Summer mode
Water flow control
OCH714A
Parameters
DHW
Pump speed (1 to 5)
Heating/Cooling
Pump speed (1 to 5)
Standard/Heater/Boiler/Hybrid *11
Heat pump flow rate range Minimum(0 to 100L/min)
Maximum(0 to 100L/min)
Quiet mode
Day (Mon to Sun)
Time
Quiet level (Normal/ Level1/ Level2)
Flow temp.range
Minimum.temp.(20 to 45°C)
*13
Maximum.temp.(35 to 60°C)
Room temp.control
Mode (Normal/Fast)
*14
Interval (10 to 60min)
Heat pump thermo
On/Off *9
diff.adjust
Lower limit (−9 to −1°C)
Upper limit (+3 to +5°C)
Outdoor ambient temp. (3 to 20°C) / **
On/Off *9
Outdoor ambient temp. (−30 to +10°C) *6
On/Off *9
Outdoor ambient temp. (−30 to −10°C) *6
Hybrid settings
Intelligent set-
tings
DHW
On/Off
Target temp (+1 to +20°C) / -- (Non active)
Heating
On/Off
Target temp.
Cooling
On/Off
Target temp.
Pump cycles
Heating (On/Off)
Cooling (On/Off)
Interval(10 to 120 min)
On/Off *9
Target temp.
Flow temp.
(Increase)
Flow temp.
(Decrease)
On/Off
Outdoor ambi-
ent temp.
Judgement
time
Forced heating ON (-30 to 10°C)
On/Off
Outdoor ambient temp.
(−30 to +10°C) *6
Priority mode (Ambient/Cost/CO
*16
Outdoor ambient temp. rise
(+1
to
+5 °C)
Energy
Electricity
price
(0.001 to 999 */kWh)
*17
Boiler
(0.001 to 999 */kWh)
CO
Electricity
2
emis-
(0.001 to 999 kg -CO
sion
kWh)
Boiler
(0.001 to 999 kg -CO
kWh)
Heat
Heat pump capacity
source
(1 to 40 kW)
Boiler efficiency
(25 to 150%)
Booster heater 1 capac-
ity
(0 to 30 kW)
Booster heater 2 capac-
ity
(0 to 30 kW)
Switch-on recommendation(20 to 60°C)
Switch-on command(20 to 60°C)
Switch-on recommendation(5 to 25°C)
Switch-on command(5 to 25°C)
Start&Finish (20 to 60°C)
Max. temp. (20 to 60°C)
Max. temp. period (1 to 20 days)
Temp. increase step (+1 to +10°C)
Increase interval (1 to 7 days)
Temp. decrease step (−1 to −10°C)
Decrease interval (1 to 7 days)
Heating ON (4 to 19°C)
Heating OFF (5 to 20°C)
Heating ON (1 to 48 hours)
Heating OFF (1 to 48 hours)
88
Default
Field
Notes
setting
setting
5
5
Standard
5 L/min
100 L/min
0:00 - 23:45
Normal
30°C
50°C
Normal
10min
On
-5°C
5°C
5°C
Off
−15°C
Off
−15°C
−15°C
Ambient
2)
+3 °C
0.5 */kWh
0.5 */kWh
0.5 kg -CO
/kWh
2
/
2
0.5 kg -CO
/kWh
2
/
2
11.2 kW
80%
2 kW
4 kW
Off
--
Off
50°C
55°C
Off
15°C
10°C
On
On
10 min
Off
30°C
45°C
5 days
+5°C
2 days
−5°C
2 days
Off
10°C
15°C
6 hours
6 hours
5 °C
Off
(Continued to next page.)