Mitsubishi A8GT-50KBF User Manual

External i/o module
Hide thumbs Also See for A8GT-50KBF:

Advertisement

Quick Links

Thank you for choosing the Mitsubishi General Purpose PC Graphic Operation
Terminal 800 series. To ensure correct use of this equipment, please read this
manual carefully before operating it.
©1997 MITSUBISHI ELECTRIC CORPORATION
External I/O Module
Mitsubishi General Purpose PC
MODEL
MODEL
CODE
A8GT-50KBF
User's Manual
A8GT-50KBF-U-E
13JL28
IB-NA-66787-A (9707)MEE

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi A8GT-50KBF

  • Page 1 A8GT-50KBF External I/O Module Mitsubishi General Purpose PC User's Manual Thank you for choosing the Mitsubishi General Purpose PC Graphic Operation Terminal 800 series. To ensure correct use of this equipment, please read this manual carefully before operating it. MODEL...
  • Page 2 P.O. Box 39733, Bramley, Johannesburg 2018. Phone : (011) 444-8080 HEAD OFFICE: MITSUBISHI DENKI BLDG MARUNOUCHI TOKYO 100 TELEX: J24532 CABLE MELCO TOKYO NAGOYA WORKS: 1-14, YADA-MINAMI 5, HIGASHI-KU, NAGOYA, JAPAN When exported from Japan, this manual does not require application to the Ministry of International Trade and Industry for service transaction permission.
  • Page 3 Also pay careful attention to safety and handle the module properly. These precautions apply only to Mitsubishi equipment. Refer to the CPU module user's manual for a description of the PC system safety precautions.
  • Page 4 [INSTALLATION PRECAUTIONS] DANGER ! When installing and removing this module from the GOT main module be sure to shut off the power at all external switches. If all the switches are not turned off, the module could be damaged or malfunction. ! When connecting the bus connection cable to this module be sure to turn off the switch to all external power switches to the GOT and PC CPU.
  • Page 5 [WIRNG INSTRUCTIONS] CAUTION ! The communication and power cables connected to the module must be fixed securely, e.g. contained in ducts or clamped. A failure to do so could cause the cables to dangle, move, or be carelessly pulled, leading to a damaged module or cable or a malfunction due to a cable connection fault.
  • Page 6 [DISPOSAL PRECAUTIONS] CAUTION ! When disposing of this product, treat it as industrial waste.
  • Page 7 This manual confers no industrial property rights or any rights of any other kind, nor does it confer any patent licenses. Mitsubishi electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual.
  • Page 8 About This Manual The following product manuals are available. Please use this table as a reference to request the appropriate manual as necessary. Detailed Manual Manual No. Manual Name (Type Code) A850GOT Graphic Operation Terminal User's Manual IB-66669 (Packaged with the A850GOT) (13J847) A852GOT Graphic Operation Terminal User's Manual IB-66767...
  • Page 9: Table Of Contents

    Table of Contents Overview ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• 1 Components Including in the Package ••••••••••••••••••• 1 Specifications •••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• 2 System configuration •••••••••••••••••••••••••••••••••••••••••••••••••• 7 4.1 System Configuration for No Outputs ••••••••••••••••••••••••••••••••••••••••••••••••••• 7 4.2 System Configuration for Outputs ••••••••••••••••••••••••••••••••••••••••••••••••••••••••• 8 4.2.1 System configuration ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• 8 4.2.2 Connection of external I/O unit and terminal block conversion unit.
  • Page 10: Overview

    This user's manual gives the specifications, system configurations, parts identification, installation procedure and outline dimensions of the A8GT-50KBF type external I/O unit (referred to as the external I/O unit). The external I/O unit is fitted to the A85 GOT type graphic operation terminal (referred to as the GOT) to receive up to 8/64 points of inputs and provide up to 16 points of outputs.
  • Page 11: Specifications

    Specifications Input Specifications Input system Dynamic scan Number of input points 8/64 points Isolation system Photocoupler isolation Rated input voltage 12VDC 24DVC Rated input current Approx. 9mA Approx. 4mA Operating voltage range 10.2 to 26.4VDC (ripple percentage within 5%) Max. number of 100% simultaneous ON (at 26.4VDC) simultaneous input points ON voltage/ON current...
  • Page 12 I/O Specifications External connection system 40-pin connector Applicable wire size 0.3mm Operation indicator None 12/24VDC External Voltage* (10.2 to 26.4V, ripple percentage 5% or less) supply 1.65A for external output power Current 0.05A for internal consumption only Fuse rating* 2A fuse, unreplaceable Internal current consumption 0.10A Weight...
  • Page 13 External Connector Pin-Outs View from the unit front Connector used: Fujitsu's FCN-364P040-AU B1 B2 B3 B4 B5 B6 B7 B8 B9 B10B11B12B13B14B15B16B17B18B19B20 A1 A2 A3 A4 A5 A6 A7 A8 A9 A10A11A12A13A14A15A16A17A18A19A20 Pin Numbers and Signal Names of External Connector Pin Number Signal Name Pin Number...
  • Page 14 External Connection Diagram (1) (8-point inputs, 16-point outputs) Pin number Internal control circuit Internal XSCN0 control XSCN1 Internal XSCN2 circuit scan is XSCN3 made at XSCN4 XSCN5 1/8 duty. XSCN6 XSCN7 Internal control circuit 17A,17B,18A Fuse-blown 18B,19A detector circuit DC12/24V *1: A fuse-blown error will also be displayed when the external supply power switches off.
  • Page 15 External Connection Diagram (2) (64-point inputs, 16-point outputs) Pin number Internal Input terminals control circuit Internal XSCN0 control XSCN1 Internal XSCN2 circuit scan is XSCN3 made at XSCN4 XSCN5 1/8 duty. XSCN6 XSCN7 Internal control circuit 17A,17B,18A Fuse-blown 18B,19A detector circuit DC12/24V *1: When there is a probability that two or more switches are pressed...
  • Page 16: System Configuration

    System Configuration The system configuration depends on whether the external I/O unit provides outputs or not. System Configuration for No Outputs Inputs Connection cable (Originaloperator panel) DC power supply 12/24V User-fabricated User-fabricated External I/O unit A8GT-50KBF A85 GOT...
  • Page 17: System Configuration For Outputs

    (e.g.pushbuttons) conversion unit (e.g.lamps,relays) LAMP DC poewr supply 12/24V A6TBY36-E,A6TBY54-E Connection cable External I/O unit A8GT-50KBF A85 GOT A8GT-C30TB •1 The cable for connection between external I/O unit and terminal block conversion unit may also be fabricated by the user.
  • Page 18: Operator Panel

    (2) For 64-point inputs Inputs(Original Connection cable operator panel) User-fabricated User-fabricated Outputs Terminal block (e.g.lamps,relays) conversion unit LAMP DC poewr supply 12/24V A6TBY36-E,A6TBY54-E Connection cable External I/O unit A8GT-70KBF A870GOT/A810GOT A8GT-C30TB – •1 The cable for connection between external I/O unit and terminal block conversion unit may also be fabricated by the user.
  • Page 19 4.2.2 Connection between the external I/O unit and terminal block conversion unit (1) For use of the terminal block conversion unit (A6TBY36-E) Cable for connection between external I/O unit and terminal block A8GT-50KBF conversion unit Shield XSCN0 XSCN1 XSCN2 XSCN3...
  • Page 20 (2) For use of the terminal block conversion unit (A6TBY54-E) Cable for connection between external I/O unit and terminal block A8GT-50KBF conversion unit Shield XSCN0 XSCN1 XSCN2 XSCN3 XSCN4 XSCN5 XSCN6 XSCN7 A6TBY54-E YD10 YD11 YD12 YD13 YD14 YD15 LOT24/12...
  • Page 21 4.2.3 Connection of external inputs and external outputs to the terminal block conversion unit. (1) For use of the terminal block conversion unit (A6TBY36-E) Load Load Load Load Load Load Load Load Load Load Load Load Load Load Load Load...
  • Page 22 (2) For use of the terminal block conversion unit (A6TBY54-E) Load Load Load Load Load Load Load Load Load Load Load Load Load Load Load Load...
  • Page 23 5. User-fabricated Connection Cables The following is the way of fabricating the connection cable which can be fabricated by the user. Cable for connection between external I/O unit and original operator panel Fabricate the connection cable in accordance with the following wiring diagram, parts diagram and assembly drawing.
  • Page 24 (2) Parts list Part Name Type Quantity Maker number Connector FCN-361J040-AU FUJITSU connector FCN-360C040-B cover paired sealed Electric 26 × 20P • UL 2464 AWG cable Cable Co.,Ltd UL 1015 AWG14 or equivalent • FG cable Cable for connection of •...
  • Page 25 cable for connection between external I/O unit and terminal block conversion unit. Fabricate the connection cable in accordance with the following wiring diagram, parts diagram and assembly drawing. (Max cable length:10m(32.81feet)) (1)A wiring diagram Original operator External I/O panel side unit side Signal Signal...
  • Page 26 (2) Parts list Part Name Type Quantity Maker number Connector FCN-361J040-AU FUJITSU connector FCN-360C040-B cover paired sealed Electric 26 × 20P • UL 2464 AWG cable Cable Co.,Ltd UL 1015 AWG14 or equivalent • FG cable (3) Assembly 1) 2) 1) 2) POINT ·...
  • Page 27: Parts Identifcation

    Parts Identification A8GT-50KBF MITSUBISHI Name Description Interface for connection of the I/O I/O cable connection interface cable Screws used to fix the unit to the Unit fixing screws Connector used to plug the unit to Connector the GOT. • Rating plate...
  • Page 28: Installation Procedure

    7. Installation Procedure Mount or dismount the module to or from the GOT in the following 1)Thread external I/O module mounting screw holes in the control box or the like. (2- • 3.5 mounting holes) The external I/O module's GOT connection cable is 50cm long. Install the external I/O module within this distance so that the GOT-end connector of the cable may be fitted into the GOT's connector.
  • Page 29 GOT main unit ,refer to the A8GT-50STE Option Module Mounting Bracket User’s Manual. The STE is a mounting bracket used to install the option module (A8GT-50PRF,A8GT-50KBF) to the A85 GOT main unit. When using the STE The option module can be fitted to the GOT main unit.
  • Page 30: Outline Dimension Drawing

    Outline Dimension Drawing Unit:mm(inch) A8GT-50KBF MITSUBISHI 3.2(0.13) 92(3.62) 42.6(0.13) (0.37) 105(4.13) 44(1.73)
  • Page 31: Appendix

    Appendix Appendix 1 Depth Diagram for Use of the STE A8GT-50STE Option module A85 GOT 6(0.24) 47.6(1.88) 130(5.12) 109.6(4.32) Unit:mm(inch)

This manual is also suitable for:

A8gt-50kbf-u-e

Table of Contents