Notes for operators and responsible maintenance personnel
★ Please read through this Instruction Manual as well as the separate Instruction Manual "Safety
(MN1-6105)" and "Cleaning, Disinfection and Sterilization (MN1-6117)" carefully prior to use.
★ Keep this Instruction Manual together with the ultrasound diagnostic instrument for any future
reference.
DM# 126288 V1
MXS2ESLL1 Probe
Instruction Manual
Specification
Tokyo, Japan
© Hitachi, Ltd. 2017. All rights reserved.
i
MN1-6403 Rev. 1

Advertisement

Table of Contents
loading

Summary of Contents for Hitachi MXS2ESLL1 Probe

  • Page 1 (MN1-6105)” and “Cleaning, Disinfection and Sterilization (MN1-6117)” carefully prior to use. ★ Keep this Instruction Manual together with the ultrasound diagnostic instrument for any future reference. Tokyo, Japan MN1-6403 Rev. 1 © Hitachi, Ltd. 2017. All rights reserved. DM# 126288 V1...
  • Page 2 MN1-6403 Rev. 1 DM# 126288 V1...
  • Page 3 MN1-6403 Rev. 1 Introduction This is the instruction manual for MXS2ESLL1 probe. The probe is available by connecting to Hitachi’s ultrasound diagnostic instrument and can be mainly used for observations of the heart. Prior to use, read this manual as well as the separate instruction manual “Safety” in which information for safe use is provided.
  • Page 4: Table Of Contents

    MN1-6403 Rev. 1 CONTENTS 1. General Information ...........................1 1-1. Intended use ...................................1 1-2. Classification of ME equipment ............................1 1-3. Standard components ..............................1 1-4. Options ..................................1 2. Specifications and Parts name ........................3 2-1. Specifications .................................3 2-2. Specifications of the bite block .............................4 2-3.
  • Page 5: General Information

    • Method of sterilization ..................Refer to the separate instruction manual “Cleaning, Disinfection and Sterilization” 1-3. Standard components The standard components of MXS2ESLL1 probe are as follows. MXS2ESLL1 Probe ················································· 1 set Bite block SP-7901 ··················································· 2 set Storage case ··························································· 1 set Instruction Manual •...
  • Page 6 MN1-6403 Rev. 1 DM# 126288 V1...
  • Page 7: Specifications And Parts Name

    At the time of publication of this manual, the connectable diagnostic ultrasound instrument or instrument software version available with this probe is different for each country, please refer to the instrument instruction manual or contact your local Hitachi representative. Field of view: 90°...
  • Page 8: Specifications Of The Bite Block

    MN1-6403 Rev. 1 2-2. Specifications of the bite block Material Polyetherimide Service life Three years External dimensions As shown in the figure below. Unit: mm Remarks: The tolerance for the dimensions is ±10%. Figure 2 External view of the bite block 2-3.
  • Page 9: Name Of Each Parts

    MN1-6403 Rev. 1 2-4. Name of each parts The name of each part is shown in Figure 2 and the explanation for each part is listed in Table 2. Angle knob for U/D defrection Cable Angle knob for L/R defrection Ring Lock lever Rotation Switch A ,B...
  • Page 10 MN1-6403 Rev. 1 Table 2 Name of each part and its explanation Name Explanation Ultrasound is radiated from this part. The electronic Sector Ultrasonic irradiation part transducer is integrated underneath this part. This contains a temprature sensor controlling surface Probe tip temperature and a transducer.
  • Page 11: Preparations Before Use

    MN1-6403 Rev. 1 3. Preparations before use This chapter describes preparations needed to use the probe safely. Please prepare the probe prior to each use by following the instructions below. 3-1. Visual check Visually and tactually make certain that any of the following abnormalities has not taken place: Insertion portion is free from holes, dents, scratches, cracks, deformations, color changes and the like on the surface.
  • Page 12 MN1-6403 Rev. 1 DM# 126288 V1...
  • Page 13: Operation

    If the transducer cover is not used and will contact Lignocaine Hydrochloride such as xylocaine jelly or gel , this may cause exterior deterioration. Use Hitachi-approved transducer cover only. If use transducer cover which not reccomended can cause an adverse reaction by the body of the patient..
  • Page 14: Insertion Of Probe

    MN1-6403 Rev. 1 Caution Check the transducer cover for abnormalities before use. Regarding the storage of the transducer cover, follow the instructions of the back side of the outside bag of the transducer cover. Check that the acoustic medium has no air bubbles inside the transducer cover that is covering the probe. Air bubbles inside the transducer cover can result in misdiagnosis caused by overlooking or misinterpreting lesions due to poor image quality or improper rendering.
  • Page 15: Manipulation Of Probe

    MN1-6403 Rev. 1 4-4. Manipulation of Probe An image of the region of interest is displayed on the monitor of the ultrasound diagnostic instrument. For details on displaying and adjusting the image, refer to the documentation supplied with the ultrasound diagnostic instrument. Warning If the probe gets bent in the esophageal (J turn), do not try to move the probe by force.
  • Page 16 MN1-6403 Rev. 1 Caution Constantly check for anything abnormal about the patient’s condition and the equipment. Continued use without noticing that an abnormal condition has occurred can result in an electric shock and injury to the operator or patient. If an abnormal condition occurs, immediately move the equipment away from the patient and stop use of the probe.
  • Page 17: Manipulation Of The Deflection Portion

    MN1-6403 Rev. 1 4-5. Manipulation of the deflection portion After inserting the insertion portion into the patient’ s esophagus, flex the tube as indicated below in order to observe the target region. DOWN Turn the angle knob(for U/D operation) to countercrockwise direction to bend the defrectin portion in the in the ultrasound irradiation area side.
  • Page 18: Manipulation Of The Rotation Switch

    MN1-6403 Rev. 1 4-6. Manipulation of the rotation switch After inserting the insertion portion of the probe into the esophagus of the patient, rotate the diagnostic image using the method shown in the figure below, in order to observe the region of interest. The angle indication is a reference level.
  • Page 19: Manipulation Of The Lock Lever

    MN1-6403 Rev. 1 Bi plane Mode Switch A Turn the Bi plane mage to +direction Switch B Turn the Bi plane image to -direction Switch C Turn the Bi plane image by step to +direction Bi-plane image Reference image +direction -direction 4-7.
  • Page 20: Temperature Control System

    MN1-6403 Rev. 1 4-8. Temperature Control System The tip of the probe contains a temperature sensor. This sensor monitors the surface temperature at the tip of the probe in order to prevent damage to the esophagus tissue. When the surface temperature exceed limit, the message appears on the equipment monitor. 1) When the surface temperature becomes 41°C When the surface temperature becomes 41°C, the message “Probe temperature is higher than 41.0°C”...
  • Page 21 MN1-6403 Rev. 1 -17- DM# 126288 V1...
  • Page 22 MN1-6403 Rev. 1 This page intentionally left blank -18- DM# 126288 V1...
  • Page 23 MN1-6403 Rev. 1 This page intentionally left blank -19- DM# 126288 V1...
  • Page 24 +81-3-6284-3668 http://www.hitachi.com/businesses/healthcare/index.html Overseas Offices: Hitachi Medical Systems GmbH Otto-von-Guericke-Ring 3 D-65205 Wiesbaden, Germany EU Importer: Hitachi Medical Systems Europe Holding AG Address: Sumpfstrasse 13 CH-6300 Zug, Switzerland US Importer: Hitachi Healthcare Americas Corporation Address: 1959 Summit Commerce Park, Twinsburg, Ohio 44087 Distributor MN1-6403 Rev.

Table of Contents