GE Advantium ZSC1001 Installation Instructions Manual

GE Advantium ZSC1001 Installation Instructions Manual

120v built-in speedcook oven
Hide thumbs Also See for Advantium ZSC1001:
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

31-2000002-3
MFL59060919
07-20 GEA
GE is a trademark of the General Electric Company. Manufactured under trademark license.
Installation
Instructions
Advantium
120V Built-In
SpeedCook Oven
ZSC1001
PSB9100
®

Advertisement

Chapters

Table of Contents
loading

Summary of Contents for GE Advantium ZSC1001

  • Page 1 Installation Instructions Advantium ® 120V Built-In SpeedCook Oven ZSC1001 PSB9100 31-2000002-3 MFL59060919 07-20 GEA GE is a trademark of the General Electric Company. Manufactured under trademark license.
  • Page 2: Table Of Contents

    Safety Information CONTENTS BEFORE YOU BEGIN Design Information Read these instructions completely and Models Available ..........2 carefully. Product Dimensions and Clearances ....3 IMPORTANT — Save these instructions Tools Required ..........3 for local inspector’s use. Parts Supplied ........... 3 IMPORTANT —...
  • Page 3: Product Dimensions And Clearances

    Design Information PRODUCT DIMENSIONS AND CLEARANCES 29-3/4” With Optional Side Trim (ZSC1001) 26-3/4” 21-1/2” 13” 1” ZSC1001 PSB9100 TOOLS AND PARTS REQUIRED 18–5/8” 19” (NOT SUPPLIED 3/4“ 1” • #2 Phillips screwdriver • Hand-held drill 22–3/4” 22–11/16” • High speed drill bit, 3/32 diameter •...
  • Page 4: Installation Preparation

    Installation Preparation ELECTRICAL REQUIREMENTS Single Advantium 120 Installation: This product requires a 120-volt, 60 Hz, 15-amp circuit and draws 1.8 kilowatts. This product must be connected to a supply circuit of the proper voltage and frequency. • Wire size must conform to the requirements of the National Electrical Code or the prevailing local code for this kilowatt rating.
  • Page 5 Standard Installation Preparation IMPORTANT: Always maintain 36-3/4” minimum PREPARE THE OPENING height from the floor to the cutout in any single or (CONT.) combined installation. Installation over a Warming Drawer: Construct 23-1/2” solid bottom 27” or 30” PREPARE THE OPENING - Min.
  • Page 6 Standard Installation Preparation IMPORTANT: Always maintain 36-3/4” minimum height from the floor to the cutout in any single or combined installation. PREPARE THE OPENING (CONT.) 27” or 30” Construct Installation over a Wall Oven and Warming solid bottom 23-1/2” Drawer: - Min.
  • Page 7 Flush Mount Installation Preparation (Monogram Only) IMPORTANT: Always maintain 36-3/4” minimum height from the floor to the cutout in any single or combined installation. PREPARE THE OPENING PREPARE THE INTERIOR Cut and install side cleats: The Advantium 120 can be installed in combination with other Built-In Appliances.
  • Page 8 Flush Mount Installation Preparation (Monogram Only) IMPORTANT: Always maintain 36-3/4” minimum height from the floor to the cutout in any single or combined installation. PREPARE THE OPENING 23-1/2” min. The Advantium 120 can be installed beside another Advantium 120 in a side-by-side combination. Double Advantium 120 Installation: Cut the opening in a cabinet to the dimensions shown.
  • Page 9: Step 2 Install Bottom Trim

    Installation STEP 1 SLIDE OVEN INTO CUTOUT STEP 3 INSTALL SIDE TRIM FOR 30” CABINET INSTALLATION ONLY. Two people are required to CAUTION SKIP THIS STEP IF YOU HAVE 27” WIDE lift the oven into the opening. CABINETRY. Grasp the bottom at the front and rear. DO NOT USE THE HANDLE TO LIFT THE OVEN.
  • Page 10 NOTE: While performing installations described in this book, safety glasses or goggles should be worn. NOTE: Product improvement is a continuing endeavor at GE Appliances. Therefore, materials, appearance and specifications are subject to change without notice. Printed in China...
  • Page 11 Instrucciones de Instalación Horno con Velocidad de Cocción Incorporada Advantium® 120V ZSC1001 PSB9100 31-2000002-3 MFL59060919 07-20 GEA GE es una marca de la Empresa General Electric. Fabricado bajo licencia de la marca registrada.
  • Page 12 Información sobre Seguridad ANTES DE COMENZAR CONTENIDOS Información de Diseños Lea estas instrucciones en su totalidad y Modelos Disponibles ..........2 atentamente. Dimensiones y Espacios de Despeje del Producto .. 3 IMPORTANTE — Conserve estas Herramientas Necesarias .......... 3 instrucciones para uso del inspector local. Piezas Suministradas ..........
  • Page 13: Información De Diseños

    Información de Diseños DIMENSIONES Y ESPACIOS DE DESPEJE DEL PRODUCTO a 29 ¾” con Moldura Lateral Opcional (ZSC1001) 26-3/4” 21-1/2” 13” 1” ZSC1001 PSB9100 HERRAMIENTAS Y PIEZAS 18–5/8” 19” REQUERIDAS (NO SUMINISTRADAS) 3/4“ 1” • Destornillador Phillips nº 2 22–3/4” 22–11/16”...
  • Page 14: Preparación De La Instalación

    Preparación de la Instalación REQUISITOS ELÉCTRICOS Instalación Simple del Advantium 120: Este producto requiere un circuito de 120 voltios, 60 Hz, 15 amperes y consume 1.8 kilowatts. Este producto se debe conectar a un circuito con un suministro correcto de voltaje y frecuencia. •...
  • Page 15: Preparación De La Abertura (Estándar)

    Standard Installation Preparation IMPORTANTE: Siempre deje una altura mínima de 36 3/4” desde el piso hasta el recorte en cualquier instalación, ya sea simple o combinada. PREPARACIÓN DE LA ABERTURA PREPARACIÓN DE LA ABERTURA Instalación sobre un cajón calentador (CONT.) El Advantium 120 se podrá...
  • Page 16 Preparación para la Instalación Estándar IMPORTANTE: Siempre deje una altura mínima de 36 3/4” desde el piso hasta el recorte en cualquier instalación, ya sea simple o combinada. PREPARACIÓN DE LA ABERTURA Construya un 27” o 30” fondo sólido, (CONT.) 23-1/2”...
  • Page 17 Preparación de la Instalación para el Montaje al Ras (Monogram Únicamente) IMPORTANTE: Siempre deje una altura mínima de 36 3/4” desde el piso hasta el recorte en cualquier instalación, ya sea simple o combinada. PREPARE EL INTERIOR PREPARACIÓN DE LA ABERTURA Corte e instale los ristreles laterales: El Advantium 120 se podrá...
  • Page 18 Preparación de la Instalación para el Montaje al Ras (Monogram Únicamente) IMPORTANTE: Siempre deje una altura mínima de 36 3/4” desde el piso hasta el recorte en cualquier instalación, ya sea simple o combinada. Mín. de 23-1/2” PREPARACIÓN DE LA ABERTURA El Advantium 120 puede ser instalado junto a otro Advantium 120 combinando uno al lado del otro.
  • Page 19: Instrucciones De Instalación

    Instrucciones de Instalación PASO 1 DESLICE EL HORNO POR PASO 3 INSTALACIÓN DE LA LA ABERTURA MOLDURA LATERAL PARA LA INSTALACIÓN DEL GABINETE Se requiere contar con dos PRECAUCIÓN E 30” ÚNICAMENTE. SALTEE ESTE PASO personas para colocar el horno en la abertura.
  • Page 20 NOTA: Al realizar las instalaciones descriptas en este libro, se deberán usar anteojos o gafas de seguridad. NOTA: GE Appliances se esfuerza de forma constante para mejorar sus productos. Por lo tanto, los materiales, el aspecto y las especificaciones están sujetos a cambios sin aviso previo.

This manual is also suitable for:

Advantium psb9100

Table of Contents