Download Print this page

AEG SLH 25/L5 ST Installation Manual page 15

Fully wired self-limiting ribbon heater with thermostat

Advertisement

Available languages

Available languages

  • ENGLISH, page 10
8. Specification
8.1
output diagram
40
35
30
25
20
15
10
5
0
-30
-10
10
X Pipe temperature [°C]
Y Heating output [W/m]
1 SLH 25
8.2 Specification
outputs to en 14511
Heating output
Values
Heat conductor load
W/m
electrical details
Rated voltage
Power connection
application limits
Start temperature
Shutdown temperature
Dimensions
Height
mm
Width
mm
Length
mm
[Heat conductor length]
mm
Length of connecting cable mm
Versions
IP rating
Application
connections
Power cable
30
50
70
slH 25/l5 st
slH 25/l10 st
232559
W
125
25
V
230
1/N/PE~230 V
1/N/PE~230 V
°C
5
°C
13
11
5.6
7500
5000
2500
IP67
Ribbon heater
Ribbon heater
Standard plug,
Standard plug,
connecting cable
connecting cable
2.5 metres long
2.5 metres long
1
slH 25/l15 st
slH 25/l20 st
232560
232561
250
375
25
25
230
230
1/N/PE~230 V
5
5
13
13
11
11
5.6
5.6
12500
17500
10000
15000
2500
2500
IP67
IP67
Ribbon heater
Standard plug,
connecting cable
connecting cable
2.5 metres long
2.5 metres long
Installation - for contractors
slH 25/l25 st
232562
232563
500
625
25
230
230
1/N/PE~230 V
1/N/PE~230 V
5
13
11
5.6
22500
27500
20000
25000
2500
2500
IP67
IP67
Ribbon heater
Ribbon heater
Standard plug,
Standard plug,
connecting cable
2.5 metres long
slH 25/l30 st
232564
750
25
25
230
1/N/PE~230 V
5
5
13
13
11
11
5.6
5.6
32500
30000
2500
IP67
Ribbon heater
Standard plug,
connecting cable
2.5 metres long
15