1
4
Step 1: To dismantle the luminaire, push the lock/unlock button, slide the luminaire to the left and pull it
down.
Step 2: To gain access to the battery, lift the inner plastic cover (on top of the luminaire).
Step 3: Connect the battery cable to its respective connector on the PCB.
Step 4: In case you use a module connect it on the PCB.
Step 5: The control of maintained or non maintained operation of the luminary is achieved through Switch
4 of DS1. For maintained operation, switch number 4 must be in ON position. For non-maintained
operation, switch number 4 must be in OFF position.
The user can select one of the 3 available minimum autonomy durations: 1 hour, 3 hours and 8
hours. The selection must be done while the luminaire is disconnected from AC and battery
supplies. The selection is achieved through Switches 2 & 3 of DS1. Switch 1 is not used.
Two additional labels are included in the package, one for 3 hours duration (180) and one for 8
hours duration (480). Depending on the selected duration, the installer must remove the default 1
hour (60) label and replace it with one that has the required duration.
Honeywell Life Safety AS, Po. Box 3514, N-3007 Drammen, Norway
MaxLED
MaxLED 47m
460mm
52mm
2
5
MaxLED 65m
700mm
52mm
3
1 2 3 4
1 2 3 4
1h
3h
(default position)
1 2 3 4
Switch 4 = ON
Maintained operation
(default position)
http://www.hls-nordic.com
GB
1 2 3 4
8h
1 2 3 4
Switch 4 = OFF
Non-maintained
operation

Advertisement

loading

Summary of Contents for Honeywell MaxLED 26m

  • Page 1 Two additional labels are included in the package, one for 3 hours duration (180) and one for 8 hours duration (480). Depending on the selected duration, the installer must remove the default 1 hour (60) label and replace it with one that has the required duration. Honeywell Life Safety AS, Po. Box 3514, N-3007 Drammen, Norway http://www.hls-nordic.com...
  • Page 2 At the end of their useful life the packaging, product and batteries should be disposed of via a suitable recycling centre. Do not dispose of with your normal household waste. Do not burn. Honeywell Life Safety AS, Po. Box 3514, N-3007 Drammen, Norway http://www.hls-nordic.com...
  • Page 3 LED will flash during this test sequence. Resetting errors Push the test button for a time space between 10 and 15 seconds to delete all indicated errors. Then the luminaire enters regular operation mode. Honeywell Life Safety AS, Po. Box 3514, N-3007 Drammen, Norway http://www.hls-nordic.com...

This manual is also suitable for:

Maxled 47mMaxled 65m138009138254138255