Functional Description; Installing Or Removing Battery Cartridge; Overload Protection; Overdischarge Protection - Makita DUB361 Instruction Manual

Cordless blower
Hide thumbs Also See for DUB361:
Table of Contents

Advertisement

FUNCTIONAL
DESCRIPTION
CAUTION:
Always be sure that the tool is switched off and
the battery cartridge is removed before adjust-
ing or checking function on the tool.
Installing or removing battery
cartridge
3
► 1 . Red indicator 2. Button 3. Battery cartridge
CAUTION:
Always switch off the tool before installing or
removing of the battery cartridge.
Hold the tool and the battery cartridge firmly
when installing or removing battery car-
tridge. Failure to hold the tool and the battery
cartridge firmly may cause them to slip off your
hands and result in damage to the tool and
battery cartridge and a personal injury.
To remove the battery cartridge, slide it from the tool
while sliding the button on the front of the cartridge.
To install the battery cartridge, align the tongue on the
battery cartridge with the groove in the housing and slip
it into place. Insert it all the way until it locks in place
with a little click. If you can see the red indicator on the
upper side of the button, it is not locked completely.
CAUTION:
Always install the battery cartridge fully until the
red indicator cannot be seen. If not, it may acci-
dentally fall out of the tool, causing injury to you
or someone around you.
Do not install the battery cartridge forcibly. If the
cartridge does not slide in easily, it is not being
inserted correctly.
NOTE:
The tool does not work with only one battery
cartridge.
Tool / battery protection system
The tool is equipped with a tool/battery protection sys-
tem. This system automatically cuts off power to the
motor to extend tool and battery life.
The tool will automatically stop during operation if the
tool or battery are placed under one of the following
conditions. In some conditions, the indicators light up.

Overload protection

When the tool is operated in a manner that causes it to
draw an abnormally high current, the tool automatically
stops without any indication. In this situation, turn the
tool off and stop the application that caused the tool to
become overloaded. Then turn the tool on to restart.
1
Overheat protection for battery
When the battery is overheated, the tool stops auto-
2
matically without any indication. The tool does not start
even if pressing the switch button. In this situation, let
the battery cool before turning the tool on again.
NOTE: The battery overheat protection works only
with a battery cartridge with a star marking.
► 1 . Star marking

Overdischarge protection

► 1 . Battery indicator
When the remaining battery capacity gets low, the
battery indicator blinks on the applicable battery side.
By further use, the tool stops and the battery indicator
lights up about 10 seconds. In this situation, charge the
battery cartridge.
4 ENGLISH