Idle Drive Failure Detection - Acer AcerAltos 3102RS User Manual

Ultra-scsi to ultra-scsi raid controller
Table of Contents

Advertisement

Use t or s to choose the desired
interval for "Auto Checking Drive Hot
Swap," and then press <ENT> to
confirm. If a member drive of a logical
drive fails, the controller will start to
check the failed drive to check if it has
been replaced (i.e., the controller checks
the same drive channel and ID at the
assigned interval.) Once the drive has
been replaced with another drive, the
controller
will
automatically
rebuild to that replacement drive.

Idle Drive Failure Detection

From the Main Menu, use t and s to
select "View and Edit Configuration
Parameters."
Press t or s to choose "Drive-side
SCSI Parameters," and then press
<ENT>.
Use t or s to select "Periodic Drive
Check Time - Disable," and then press
<ENT>.
Use t or s to choose the desired
interval for idle drive failure detection.
By choosing a time value to enable the "Periodic
Drive Check Time", the controller will poll all of the
connected drives in the controller's drive channels at
the assigned interval. Drive removal will be detected
even if a host does not attempt to access data on
the drive.
118
Set Drv Swap Chk
Time - 5 sec
start
to
View and Edit
Config Parms
Drive-side SCSI
Parameters
Periodic
ChkTime -Disable
AutoChk -Disable
Set Drive Check
Time 1/16sec ?
..
Drive
User's Guide

Advertisement

Table of Contents
loading

Table of Contents