Cooling Time; Residual Moisture Level; Extra Drying Time - Electrolux TT300 Operating And Installation Manual

Table of Contents

Advertisement

Parameter no.
check by pressing
the clock button

Cooling time

Running time
without
heat at end of
Cooling time
cycle

Residual moisture level

The measurement of residual moisture level consists of a combined parameter set for residual
moisture + a parameter for extra drying time.
Residual
moisture level,
F0 = ready
Program
to put away
P1 =
extra dry
Residual
moisture level,
F0 = ready
Program
to put away
P2 =
ready to put away
Residual
moisture level,
e.g. 30 =
Program
iron dry
P3 =
ironing dry

Extra drying time

Extra drying
time
in minutes
Program
P1 =
extra dry
Extra drying
time
in minutes
Program
P2 =
ready to put away
Extra drying
time
in minutes
Program
P3 =
ironing dry
487 18 39 01 - 300/500/750 - GB
Parameter programming
Value
can be set after two seconds
Can be set to a value
between 00 and 10 minutes.
Factory setting = 03
Can be set to a value
between 05 and F0.
Factory setting F0
Can be set to a value
between 05 and F0.
Factory setting F0
Can be set to a value
between 05 and F0.
Factory setting 30
Can be set to a value
between 00 and 20 minutes.
Factory setting 09
Can be set to a value
between 00 and 20 minutes.
Factory setting 03
Can be set to a value
between 00 and 20 minutes.
Factory setting 00
Required change:
Press the "count up/down" buttons.
Count down
Count up
The values for residual moisture are
given in hexadecimals (05-F0). See
explanation on following page.
Extra drying time when the value set
in parameter 09 has been reached.
Extra drying time when the value set
in parameter 10 has been reached.
Extra drying time when the value set
in parameter 11 has been reached.