User Manual
SAMSUNG ARM BPM EI-B5000
CATALOGUE
Thank you very much for selecting SAMSUNG ARM BPM EI-B5000.
To use the monitor correctly and safely, please read the manual thoroughly.
Please keep well this manual in order to reference in future.
Guangdong Transtek Medical Electronics Co., Ltd.
Zone A, No.105 ,Dongli Road, Torch Development District,
Zhongshan,528437,Guangdong,China
EC REP
version:1.0
Arm Type

Table of Contents

INTRODUCTION...................................................................................................................2
BEFORE YOU START...........................................................................................................8
The Choice of Power Supply
Installing and Replacing the Batteries
D
MEASUREMENT..................................................................................................................11
INFORMATION FOR USER.................................................................................................14
Maintenances
ABOUT BLOOD PRESSURE...............................................................................................16
Why do I get a different blood pressure at home compared to the hospital?
Is the result the same if measuring on the right arm?
TROUBLESHOOTING.........................................................................................................18
SPECIFICATIONS................................................................................................................19
CONTACT INFORMATION...................................................................................................20
FCC STATEMENT...................................................................................................
COMPLIED STANDARDS LIST...........................................................................................21
EMC GUIDANCE.................................................................................................................22
CATALOGUE
1

Advertisement

Table of Contents
loading

Summary of Contents for Samsung ARM BPM

  • Page 1: Table Of Contents

    Maintenances ABOUT BLOOD PRESSURE....................16 What are systolic pressure and diastolic pressure? Thank you very much for selecting SAMSUNG ARM BPM EI-B5000. What is the standard blood pressure classification? To use the monitor correctly and safely, please read the manual thoroughly.
  • Page 2: Introduction

    Symbol for “THE OPERATION Symbol for “TYPE BF APPLIED GUIDE MUST BE READ” PARTS” Thank you for selecting arm type SAMSUNG ARM BPM ( EI-B5000 ). The Symbol for “ENVIRONMENT monitor features blood pressure measurement, pulse rate measurement and Symbol for “MANUFACTURER”...
  • Page 3 * The equipment is not AP/APG equipment and not suitable for use in the presence of a contact the SERVICE PERSONNEL of SAMSUNG. Don’t open or repair the device by flammable anesthetic mixture with air of with oxygen or nitrous oxide.
  • Page 4: Led Display Signal

    * There is no luer lock connectors are used in the construction of tubing, there is a possibility that they might be inadvertently connected to intravascular fluid systems, allowing air to be 2. Cuff (22~42cm) 1. SAMSUNG ARM BPM pumped into a blood vessel. (Type BF applied part) (EI-B5000) * Please use the device under the environment which is provided in the user manual.
  • Page 5: Before You Start

    Remove the old batteries from the device following your local recycling guidelines. Install the App and Pair-Up Download the SAMSUNG HEALTH app from APP Store or Google Play. Search your test information Install the APP, and register an account. Click “Manage items”...
  • Page 6: Measurement

    BEFORE YOU START MEASUREMENT RF Frequency Range : 2402MHz to 2480MHz START/STOP BUTTON Output Power Range : ≤ 0 dBm Supply Voltage : 4.0-7.2V Transmitting Distance : 10 meters List of compatible devices: For iOS devices: The operating system must be iOS 8 or more, such as iPhone 4S, iPhone 5/5C/5S, iPhone 6/6 Plus and so on.
  • Page 7: Taking A Measurement

    MEASUREMENT MEASUREMENT After the measurement was finished, the Systolic pressure, Diastolic Take the measurement in a silent room. pressure and heart rate will show up alternately The patient must relax as much as possible and do not move and talk during the measurement procedure.
  • Page 8: Information For User

    INFORMATION FOR USER INFORMATION FOR USER Maintenance Tips for Measurement In order to get the best performance, please follow the Measurements may be inaccurate if taken in the following instructions below. circumstances. Avoid touching water, Put in a dry place and avoid the sunshine clean it with a dry cloth in case.
  • Page 9: About Blood Pressure

    During each measurement, if measuring on the SAMSUNG ARM BPM will keep a record of all the pulse intervals and calculate the average value of them. If there are two or more pulse intervals, the difference right arm? between each interval and the average is more than the average value of ±25%, or...
  • Page 10: Troubleshooting

    Measurement mode Oscillographic testing mode SAMSUNG ARM BPM. If the products not operating as you think it Rated cuff pressure: should, check here before arranging for servicing. 0mmHg~299mmHg (0kPa ~ 39.9kPa)
  • Page 11: Contact Information

    Contact Information COMPLIED STANDARDS LIST Contact Information -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. For more information about our products, please visit www.transtekcorp.com. -- Connect the equipment into an outlet on a circuit different from that to which you can get customer service, usual problems and customer download, Transtek the receiver is connected.
  • Page 12: Emc Guidance

    EMC GUIDANCE EMC GUIDANCE Table 1 Guidance and manufacturer’s declaration - electromagnetic emissions EN 60601-1-6:2010+A1:2015/IEC 60601-1-6:2010+A1:2013 Medical Emissions test Compliance electrical equipment - Part 1-6: General requirements for basic safety Usability and essential performance - Collateral standard: Usability IEC 62366-1:2015 Medical devices - Part 1: Application of usability RF emissions Group 1 engineering to medical devices...
  • Page 13 EMC GUIDANCE EMC GUIDANCE Pulse Voltage dips, short Not applicable Not applicable 800-960 800/900, modulation b) interruptions and TETRA 800, 18Hz voltage variations iDEN 820, on power supply CDMA 850, input lines LTE Band 5 IEC 61000-4-11 GSM 1800; Pulse 1720 1700- modulation b)