Panasonic LC2H Series Manual

Panasonic LC2H Series Manual

Din half size lcd counter

Advertisement

Quick Links

LC2H
Panel mounting type
One-touch installation type
Panel mounting type
Installation frame type
PC board mounting type
RoHS Directive compatibility information
http://www.nais-e.com/
Product chart
Installation type
Panel
One-touch installation type
mounting
Installation frame type
type
PC board mounting type
Product types
1. Panel mounting type
1) One-touch installation type
1 Standard type
No. digits
Counting speed
2 kHz/30 Hz switchable
8 digits
Note) Please ask us about types without front resetting.
2 Backlight type
No. digits
Counting speed
8 digits
2 kHz/30 Hz switchable
Features
1. 8.7 mm
(previously 7 mm)
Easy-to-read character height increased
from 7 mm to 8.7 mm
inch.
2. Plenty of Digits
3. Counting Speed Switchable
between 2 kHz and 30 Hz
4. Panel Mounting Type Features
2 Installation Methods
Comes with very easy one-touch
installation type and also installation
frame type that uses the bracket on the
timer/counter. Choose a method that
suits the application.
5. Battery Replacement Easy on
Environment
To replace battery simply remove body
for the one-touch installation type, and
remove battery lid for the installation
frame type.
Type
Non-voltage input type
Front reset
Yes
30 Hz
Front reset
Yes
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
DIN HALF SIZE
LCD COUNTER
.343 inch
Character Height
.276 inch to .343
8.7mm
.343inch
8 digits
Standard type
Voltage input type
(4.5 to 30 V DC)
Input method
Non-voltage input type
Voltage input type (4.5 to 30 V DC)
Free voltage input type (24 to 240 V AC/DC)
Input method
Voltage input type (4.5 to 30 V DC)
LC2H
Counters
6. Screw Terminals Designed for
Safety
Built in finger protection.
7. Panel Covers Replacable
(Standard color is ash gray.)
Change the panel design by replacing
with a black panel cover.
8. Conforms to IP66 Protective
Construction (Only installation frame
type.) (Front panel surface)
9. Input Methods
1) Non-voltage input method
2) Voltage input method
3) Free voltage input method
10. Backlight Type Added to Series
and Now 2-color Switchable (green/
red)
Easy viewing even in dark places and
switchable between green and red
(Voltage input type).
11. Compliant with UL, c-UL and CE.
Free voltage input type
Voltage input type
(24 to 240 V AC/DC)
(4.5 to 30 V DC)
LC2H-FE-2KK
LC2H-FE-DL-2KK
LC2H-FE-FV-30
LC2H-FE-DL-2KK-B
Backlight type
Part No.
Part No.

Advertisement

Table of Contents
loading

Summary of Contents for Panasonic LC2H Series

  • Page 1 LC2H LC2H DIN HALF SIZE LCD COUNTER Counters Features 1. 8.7 mm .343 inch Character Height 6. Screw Terminals Designed for (previously 7 mm) Safety Easy-to-read character height increased Built in finger protection. from 7 mm to 8.7 mm .276 inch to .343 7.
  • Page 2: Specifications

    LC2H 2) Installation frame type 1 Standard type No. digits Counting speed Front reset Input method Part No. Non-voltage input type LC2H-F-2KK 2 kHz/30 Hz switchable 8 digits Voltage input type (4.5 to 30 V DC) LC2H-F-DL-2KK 30 Hz Free voltage input type (24 to 240 V AC/DC) LC2H-F-FV-30 Note) Please ask us about types without front resetting.
  • Page 3: Applicable Standard

    LC2H 2. PC board mounting type Type PC board mounting type Item Input method Non DC voltage input No. digits 8 digits Rated operation voltage 3 V DC Allowable operation voltage range 2.7 to 3.3 V DC Current consumption Max. 30 µA (max. 250 µA during reset input) Max.
  • Page 4: Part Names

    LC2H Part names 1. Front reset button Count speed switch COUNTER This button resets the count value. It does not work when the lock switch is ON. Be aware that battery life will RESET LC2H decrease if this switch is used frequently. 2.
  • Page 5 LC2H 2) Installation frame type • Panel mounting diagram 44.8 Mounting frame Mounting screws 1.764 ATH3803 (included) (found on mounting frame) 54.4 2.142 1.457 Rubber gasket Panel ATH3804 (included) (1 to 4.5mm .039 to .177inch thickness) 10.4 .409 1.732 .197 1.890 COUNTER .866...
  • Page 6: Input Method

    LC2H General tolerance: ±1.0 ±.039 2. PC board mounting type inch • External dimensions PC board pattern (BOTTOM VIEW) ±0.3 33.02 ±.012 1.300 ±0.3 ±0.3 5.08 5.08 Mounting area 2.54 ±.012 ±.012 .200 .200 .100 ±0.1 DIP switch × 8 ±.004 .075 .024...
  • Page 7: Explanation Of Operation

    LC2H 2. Backlight type Voltage input type Transistor input Backlight connection Contact input NPN transistor PNP transistor Green 24V DC Count Reset input input Count Reset Count Reset input input input input 24V DC Notes) 1. Do not reverse the polarities when connecting the DC voltage for the backlight. 2.
  • Page 8: Cautions For Use

    LC2H Cautions for use 1. Non-voltage input type 2) For external resetting use H level Voltage input type For both panel mounting and PC (application of 4.5 to 30 V DC) between reset terminals 3 and 4 of the rear board mounting types 1) Never apply voltage to the non-voltage terminals.

Table of Contents